Optical Parts Disassemblies
.
Locations and Directions
When the optical parts in the optical unit mounting or assembling, the
parts must be mounted in the specified location and direction as
shown in figure below.
1
2
3
The printed marker
comes this side.
4
5
The printed marker
comes this side.
6
7
8
Key No.
1
2
3
4
5
6
7
8
9
10
11
12
13
Note: The arrows in the figure are indicated that
there are the direction of part placement.
Place each part as the printed marker on the
part comes to each arrow direction.
-18-
Description
Mirror (W)
Integrator lens (OUT)
Prism beam splitter (PBS)
Dichroic mirror (B)
Condenser lens (OUT)
Dichroic mirror (G)
Relay lens (IN)
Mirror (R)
Condenser lens (R)
Condenser lens
Condenser lens (B)
Optical filter (UV cut)
Mirror (B)