Sanyo PLC-XU40 Service Manual page 10

Hide thumbs Also See for PLC-XU40:
Table of Contents

Advertisement

Mechanical Disassemblies
b
Lamp Ballast Unit removal
1
A
Remove 1 screw
(M3x4) and remove SW902, and then remove 1 screw
B
(M3x6) and disconnect the Lamp Socket.
2
C
Remove 2 screws
(M3x6) to take the Lamp Ballast ass'y upward off.
3
D
Remove 2 screws
(T2x6) to take the isolation sheet off.
4
E
Remove 4 screws
(T3x6) to take the lamp ballast board off.
D
D
Isolation sheet
Lamp ballast board
n
Filter Board removal
1
A
Remove 3 screws
(M3x6) and pull the Filter Board ass'y upward.
2
B
Remove 1 screw
(M4x8) to take the grounding lead from the cabinet bottom.
3
C
Remove 4 screws
(T3x8) to take the Filter Board off.
E
C
E
E
E
SW902
A
A
A
B
C
B
A
C
C
C
Filter board
C
-10-
Lamp ballast socket
Fig.5