Contents of adjustment mode
5.1.4.
• Value is shown as a hexadecimal number.
• Preset value differs depending on models.
• After entering the adjustment mode, take note of the value in each item before starting adjustment.
ADJUST
WB-ADJ
OPTION
SRV-TOOL
DRV CHECK
5.1.5.
Display of SOS History
SOS History (Number of LED blinking) indication.
From left side; Last SOS, before Last, three occurrence before, 2nd occurrence after shipment, 1st occurrence after shipment.
This indication except 2nd and 1st occurrence after shipment will be cleared by [Self-check indication and forced to factory
shipment setting].
5.1.6.
Exit
1. Disconnect the AC cord from wall outlet.
Main item
Sub item
CONTRAST
COLOUR
TINT
SUB-BRT
BACKLGT
H POS
H AMP
V POS
V AMP
A COM
R-GAIN
G-GAIN
B-GAIN
R-CENT
G-RENT
B-CENT
Boot
STBY-SET
EMERGENCY
CLK MODE
CLOCK
Y/C DELAY
OPT 1
OPT 2
OPT 3
OPT 4
EDID-CLK
Sample Data
8D
AE
FF
6C
80
A0
ROM
00
ON
00
FC7
DYNAMIC
00000000
11100110
00001001
00000000
HIGH
00
DYNAMIC
11