Remove The Plasma Panel Section From The Cabinet Assy; (Glass); Replace The Plasma Panel (Finished) - Panasonic TH-58PE75U Service Manual

Hide thumbs Also See for TH-58PE75U:
Table of Contents

Advertisement

6.22. Remove the Plasma panel
section from the Cabinet assy

(glass)

1. Remove the stand brackets (left, right) fastening screw (×2
each).
2. Remove the cabinet assy and the plasma panel fastening
screws (×10
).
3. For leaving the plasma panel from the front frame, pull the
bottom of the cabinet assy forward, lift, and remove.
4. Remove the spacers and spacer rings (×6
6.23. Replace the plasma panel
(finished)
1. Place the new plasma panel (finished) on the flat surface of
the table (covered by a soft cloth), with the plasma panel
surface facing downward.
2. Attach the C1-Board, C2-Board and the C3-Board, connect
the flexible cables (×22) from the plasma panel to the C1-
Board, C2-Board and the C3-Board, and fit the flexible
cable holders.
3. Attach the Hooks (left, right) and fit the stand brackets (L,
R) to the new plasma panel.
4. Place the plasma panel section on the servicing stand.
5. Attach the cabinet assy and each P.C.Board and so on, to
the new plasma panel.
*When fitting the cabinet assy, be careful not to allow
any debris, dust or handling residue to remain between
).
the front glass and plasma panel.
15
TH-58PE75U

Advertisement

Table of Contents
loading

Table of Contents