A substitute replacement that does not have the same safety characteristics as the recommended replacement part may create shock, fire and / or other hazards. Product safety is under review continuously and new instructions are issued whenever appropriate. SyncMaster 800TFT...
ESDs. Motions such as solder removal devices not classified as “anti-static” brushing clothes together, or lifting your foot from can generate electrical charges sufficient to damage a carpeted floor can generate enough static ESDs. electricity to damage an ESD. SyncMaster 800TFT...
: -68°F to 113°F (-20°C to 45°C) Humidity : 5 % to 95 % • SyncMaster 800TFT complies with SWEDAC (MPR II) recommendations for reduced electromagnetic fields. • Designs and specifications are subject to change without prior notice. SyncMaster 800TFT...
No Connection No Connection Self Raster Self Raster Self Raster Bi-Dr Data (SDA) Bi-Dr Data (SDA) Bi-Dr Data (SDA) H/V-Sync Not Used H-Sync V-Sync Not Used Not Used 1, 2 DDC Clock (SCL) DDC Clock (SCL) DDC Clock (SCL) SyncMaster 800TFT...
B : Horizontal sync width O : Frame time total P : Vertical sync width C : Back porch D : Active time Q : Back porch R : Active time E : Front porch S : Front porch SyncMaster 800TFT...
3 Disassembly and Reassembly This section of the service manual describes the disassembly and reassembly procedures for the SyncMaster 800TFT TFT-LCD monitor. WARNING: This monitor contains electrostatically sensitive devices. Use caution when handling these components. 3-1 Disassembly Cautions:1. Disconnect the monitor from the power source before disassembly.
Page 10
3 Disassembly and Reassembly Memo SyncMaster 800TFT...
SIGNAL CABLE BOARD VER. 2.0 3-WIRE CABLE 5V DC 5V DC ADAPTOR 3-WIRE ADAPTOR CABLE SIGNAL CABLE PARALLEL CABLE PARALLEL CABLE D-SUB SIGNAL CONNECTOR GENERATOR Figure 4-1. Setup 1, With Signal Generator Figure 4-2. Setup 2, Without Signal Generator SyncMaster 800TFT...
PC system and to test the connection Read buffer Reload the Panel Parameter Control values from between the Control JIG and your computer the Program buffer Exit Quits the DDC Control JIG Return Main Returns to the Main menu SyncMaster 800TFT...
Page 13
Main Menu. 3. After normal execution of Auto Algorithm, confirm optimal settings by observing the contrast of several different patterns on the display. 4. If you want to check each color value, click the button from and from SyncMaster 800TFT...
Page 14
Change No. value(s). Figure 4-5. Service Function Menu Screen Note: Increment the Lamp value(s) only if one or both of them were replaced, but the Lamp was not replaced. 3. After incrementing the appropriate values, power off the monitor. SyncMaster 800TFT...
Page 15
4 Alignments and Adjustments SyncMaster 800TFT...
Does proper DC 5 V appear at Check IC101 and related circuit. Pin 4 of IC101? Does proper 5 V - signal appear at Check IC501 and related circuit. Pin 42 of IC501 (SW_REG_EN)? (CN102, Function Key) Check Q103, Q105 and Q106. SyncMaster 800TFT...
Page 17
PDA, PDB)? During power on-off dose the input signal Check IC501 and related circuit. appear at the R 407 and R 408 ? (MX - SDA, MX - SCL) Check IC 406 and related circuit. SyncMaster 800TFT...
Page 19
11 12 13 10 of IC404? CH1 RMS = 4.18V While pushing a front control button does any pulse appear Check IC404 and related circuit. at Pin 12 of IC404? CH1 RMS = 3.26V Replace IC404. CH1 RMS = 3.26V SyncMaster 800TFT...
Page 20
6 Exploded View and Parts List SyncMaster 800TFT...