Noise Criteria Curves - Mitsubishi Electric MUZ-DM25VA Service Manual

Outdoor unit of split-type air conditioner
Hide thumbs Also See for MUZ-DM25VA:
Table of Contents

Advertisement

4

NOISE CRITERIA CURVES

MUZ-DM25VA
90
80
70
60
50
40
30
20
10
63
125
250
BAND CENTER FREQUENCIES, Hz
OBH751
FUNCTION SPL(dB(A))
LINE
COOLING
50
HEATING
50
NC-10
500
1000
2000
4000
8000
MUZ-DM35VA
90
80
70
NC-70
60
NC-60
50
NC-50
40
NC-40
30
NC-30
20
NC-20
10
63
Test conditions
Cooling : Dry-bulb temperature 35°C
Heating : Dry-bulb temperature 7°C Wet-bulb temperature
MICROPHONE
6
FUNCTION SPL(dB(A))
COOLING
HEATING
NC-10
125
250
500
1000
2000
BAND CENTER FREQUENCIES, Hz
OUTDOOR UNIT
1m
LINE
51
51
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
4000
8000
6°C

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Muz-dm35va

Table of Contents