OUTDOOR PCB
CIRCUIT DIAGRAM
INVERTER ASSEMBLY
AOYG12LUC : EZ-010DHUE
TO INDOOR UNIT
L
1
N
2
SERIAL
3
L
POWER SOURCE
AC230V
50Hz
N
EARTH
WIRE W/TERMINAL ( CORE )
1015#22
GREEN
TERMINAL
2011.05.06
EMI FILTER
EMI FILTER
UL1015 AWG20
BLACK
UL1015 AWG20
WHITE
UL1015 AWG20
RED
EMI FILTER
UL1015 AWG14
BLACK
UL1015 AWG14
WHITE
UL1015 AWG16
GREEN
THERMISTOR ( PIPE TEMP. )
BLACK
BLACK
BLACK
BLACK
THERMISTOR ( DISCHARGE TEMP. )
FRAME
THERMISTOR ( OUTDOOR TEMP. )
BLACK
BLACK
W101
B
W102
B
W4
B
W1
B
W2
B
W3
B
1
CN71
2
B04B-PL I RK-1
3
RED
4
CONTROLLER PCB ASSEMBLY
AOYG12LUC : K10BO-1000HUE-C1
1
CN70
2
B03B-PL I SK-1
WHITE
3
8
COMPRESSOR
EMI FILTER
W7
RED
U
B
W8
WHITE
V
B
W9
BLACK
W
B
UL3271 AWG16 x 3
UL3271
AWG14
W10
WHITE
B
W11
UL3271
B
AWG14
RED
CN30
1
BLACK
4-WAY VALVE
2-1747052-3 or 1747052-1
2
BLACK
BLUE or WHITE
1
RED
DC FAN MOTOR
2
3
CN800
B5 ( 7-2.3 ) B-XASK-1-A
4
F M
BLACK
WHITE
5
WHITE
6
YELLOW
7
BROWN or BLUE
1
RED
CN40
2
BLUE
B05B-PL I SK-1
M
3
ORANGE
WHITE
4
YELLOW
5
WHITE
ELECTRIC
EXPANSION VALVE
M
REACTOR
13mH, 8A