Specifications - Edax Audio Labs MP-800 Operation Manual

8 channel vacuum tube microphone amplifier
Table of Contents

Advertisement

SPECIFICATIONS

Input Impedance(microphone): 2k2 ohm,nominal.
Input Impedance(direct input):1Mohms (Instrument).
Maximum input level:+23dBu into 10Kohms.
Maximum input level(DI-BOX):+10dBu.
Maximum output level:+32dBu into 10Kohms.
Output impedance:47ohms x 2.
Frequency Response: -0.75dB 20Hz and 20kHz with 10Kohm load.
Noise: EIN than -125dBu with 150 ohm input load, unweighted.
Distortion: THD+N less than 0.02%, +35dB gain
Phantom Power:+48Vdc applied to pins 2 and 3, +/- 1Vcc.
Mic Pad: -20dB attenuation.
Mic Phase switch: inverts the phase 180 degrees at the transformerless output.
Phase desviation: 0.2% at 2KHz, 0.4 at 20KHz ,+20 dBu output.
Hi Pass Filter : Passive 12 dB/octave rolloff 90Hz
Polarity: input and output XLR connectors are pin 2 hot.
Vacuum Tubes: ECC82/12AU7
Power: 100VAC to 240VAC, 50/60Hz, selectable.
Power consuption:80 watts maximum.
Dimensions: 2U enclosure, 19" x 3.5" x 14.37" (48.3 x 8.9 x 36.5 cm).
Weight: 7Kg.
Net Weight: 8Kg.
Notes: 0 dBu = 0.775 Vrms.
All noise measurements are unweighted, 20 - 20,000 Hz bandwidth.
All specifications are subject to change without notice.