S E R V I C E
Technical data
Flow rates/ Inlet volume
Flow meter (at 0.3 bar = quantity 1.1 l/min)
Spray pump
Drain pump
Pump height max.
Inlet valve
Spray arm lower
Sprayarm upper
Sprayarm/ Shower top
Fan for drying:
Total
Primary air flow
Secondary air flow
Electrical base data
Voltage
Frequency
Total power
Fuse
Spray pump motor permanent spray system
Voltage
Power consumption
HI
HA
Capacitor
Drain pump motor
Voltage
Power consumption
Resistance
Fan for drying
Voltage
Resistance
Heating - 1 Element system
Voltage
Power consumption
Resistance
Heating speed
Temperature on surface
Safety thermostat
self reset
(Temperature of water)
Fuse
Whirlpool Europe
Customer Service
208
lmp/l
65
l/min
16
l/min
1.1
m
4
l/min
~ 33
l/min
~ 27
l/min
~ 8
l/min
900
l/min
210
l/min
780
l/min
220/ 240 V
50
Hz
2.0 - 2.2
kW
10
A
220/ 240 V
140
W
69
48
µ F
4
220/ 240 V
30
W
146
220/ 240 V
141
220/ 240 V
1.87/ 2.04 kW
24.5
~ 2.0
˚C/min
~ 115
˚C
~ 85
˚C
206
˚C
ADP 4730 WH
8511 560 10810
Water safty options
Waterstop system
Single electric water inlet valve
Voltage
Frequency
Resistance
Regenerating valve
Voltage
Frequency
Resistance
Coil of dispenser
Voltage
Frequency
Resistance
Reed contacts
flow meter
salt control
rinse aid control
NTC
20 ˚C
25 ˚C
30 ˚C
40 ˚C
50 ˚C
60 ˚C
70 ˚C
80 ˚C
85 ˚C
Regeneration
Volume
after wash cycles
water hardness
Salt consumption
for regeneration
Number of cycles
with 2 kg salt
14.06.2004 / Page 3
Doc. No: 4812 728 11354
Reflex Waterstop
220/ 240 V
50/ 60
Hz
3.76
kΩ
220/ 240 V
50/ 60
Hz
3.13
kΩ
220/ 240 V
50/ 60
Hz
1.3
kΩ
58.1
kΩ
47 .1
kΩ
38.2
kΩ
25.4
kΩ
17 .2
kΩ
11.8
kΩ
8.3
kΩ
6
kΩ
4
kΩ
3
300
cm
depending on the water
softener setting
0 - 40
˚dh
0 - 10.7
mmol/l
0 - 107
˚Fh
~ 77
g
~ 26

Hide quick links: