1. Poly Spun Sediment Pre-filter - Removes sediment, particulates, dirt and rust. 2. Coconut Carbon Block Pre-filter - Removes chlorine, odor and other chemicals. 3. Reverse Osmosis Membrane - one 100 GPD filter - removes total dissolved solids. 4. Heavy-duty powder-coated hanging bracket.
Page 3
Reverse Osmosis - 200 GPD 2. Coconut Carbon Block Pre-filter - Removes chlorine, odor and other chemicals. 3. Reverse Osmosis Membrane - two 100 GPD filter - removes total dissolved solids. 4. Heavy-duty powder-coated hanging bracket. 5. Water Source Inlet Tubing, 3/8” (White) - w/ Garden Hose Connector.
Page 4
Step 2 – Starting up your RO System QUICK OPERATION GUIDE Connect the white inlet tube to your water supply and slowly turn on the water source. Once the sediment and carbon filter housings have water in them, turn The following steps will get you set up in just a few minutes. the water supply fully on.
MAINTENANCE AND FILTER CHANGES REPLACING THE RO MEMBRANE Step 1 – Unscrew the white cap from the membrane housing. The Ideal H20 Reverse Osmosis Systems have pre-filters that will need to be replaced after a certain time period of use. By keeping up with the replacement of your filters, you can double, or even triple, the life of your RO membrane.
Page 6
REPLACING THE PRE-FILTERS REPLACEMENT FILTER INFORMATION Step 1 – Unscrew the filter housing from the RO System using the filter wrench included with your system. Step 2 – Replace sediment and/or carbon block pre-filters. Step 3 – Screw the filter housing back onto the RO system, firmly hand tightening these.
Page 7
For all warranty inquiries, please contact Ideal H at (888) 582-2762. ™ Scan this QR code or visit our website for how-to videos and other product information. Exclusively distributed by: www.sunlightsupply.com...