Dacor 65089-D Installation Instructions Manual
Dacor 65089-D Installation Instructions Manual

Dacor 65089-D Installation Instructions Manual

Gas cooking appliance

Advertisement

Quick Links

SAVE AND READ THESE INSTRUCTIONS
TESTED IN ACCORDANCE WITH THE LATEST EDITION OF ANSI Z21.1 STANDARD FOR
HOUSEHOLD GAS COOKING APPLIANCES.
CONVENTIONS USED IN THESE INSTRUCTIONS
WARNINGS:
Must be followed carefully to avoid personal injury.
IMPORTANT:
Must be followed carefully to avoid damage.
NOTES:
Contain helpful hints and tips to facilitate the installation.
IMPORTANT
1. Before beginning installation, please thoroughly read and become familiar with these instructions.
2. Installation and service must be completed by a qualified installer or service agency.
3. Installer: Please leave these Installation Instructions with the owner.
4. Owner: Please keep these instructions for local electrical inspectorʼs use and for future reference.
5. Read the accompanying Use & Care Manual prior to operating this appliance.
TABLE OF STEPS
Removal and installation of backguards
Part No. 65089-D
Rev. 123003
Installation Instructions
Epicure™ Ranges
Page 2
Page 2
Page 2
Page 2-3
Page 3-4
Page 5
Page 5
Page 6
Page 6
Page 7
Page 7-8
Page 8
Page 8
Page 9
Page 9
Page 9

Advertisement

Table of Contents
loading

Summary of Contents for Dacor 65089-D

  • Page 1: Table Of Contents

    STEP 12 Gas connection Page 8 STEP 13 Installing the range Page 8 STEP 14 Installing the burner components Page 9 STEP 15 Re-installing the oven door Page 9 STEP 16 Verifying proper operation Page 9 Part No. 65089-D Rev. 123003...
  • Page 2 INSIDE FRONT COVER THIS PAGE IS BLANK INTENSIONALLY...
  • Page 3: Important Safety Instructions

    16. This appliance should be serviced only by qualified service personnel. Contact the nearest DACOR Authorized Servicer at (800) 772-7778, or at www.dacor.com for examination, repair or adjustment. Some products, such as whole eggs, and sealed containers, such as closed glass jars, may explode and should not be heated on this cooktop.
  • Page 4: Step 1

    WARNING: This appliance must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts. Electrical circuit Total Min. gas supply DACOR required connected load Gas type pressure Manifold pressure Model number...
  • Page 5: Step 4 Gas And Electrical Rough-In Locations

    STEP 4 (Continued) Gas and Electrical Rough-In Locations A manual shut valve must be installed in the gas piping, external to the appliance, for the purpose of turning on or shutting off gas to the appliance. Plan the location of the range and the gas supply to allow access to the valve when the unit is installed. Access to the remote circuit breaker panel/fuse box, with the range in place, must also be allowed for in the installation.
  • Page 6 STEP 5 (Continued) Cabinet and Countertop Preparation 3/4" (19mm) Max. backsplash 1/4" (6mm) Min. flat ledge Rear wall Rear wall Vertical Vertical non-combustible non-combustible surface surface 20 3/16" 23 3/16" (513mm) (589mm) Variable 13/16" - 3 13/16" 13/16" (21mm) (21 - 97mm) 13/32"...
  • Page 7: Step 6 Overall Dimensions

    (79mm) Backguard 19" (483mm) 15 1/4" (387mm) 9" (229mm) Backguard 3" (76mm) Accessory 3” (76mm) Side Panels Backguard (Dacor Model No. AESP03) 1 9/16" (40mm) ERD/EGR30, ERD60 Overall Dimensions Side View (ERD30 shown) 37” (940mm) Finished Side 35 3/4" Panel...
  • Page 8: Step 8 Gas Regulator And Electrical Conduit Location

    Installing the 36” and 48” Range Backguards Your DACOR range was equipped with a shipping cover to protect the internal components prior to installation. This cover must be removed and replaced by a DACOR backguard for your range to function properly.
  • Page 9: Step 10

    STEP 10 Removing the Oven Door WARNINGS: 1. Do not attempt to disengage the hinge catches with the door removed from the oven. The hinge springs could release causing personal injury. 2. Do not lift or carry the oven door by the door handle. Open the door to its fully opened position.
  • Page 10: Step 12 Gas Connection

    STEP 11 (Continued) Electrical Connection - ERD Model Ranges Only Connecting the Green Appliance Wire to the Neutral (White) Supply Wire – Where Local Codes Permit Connect the green and white appliance wires to the neutral (white) supply wire in the junction box. Connect the black appliance wire to the black (L1) power supply wire in the junction box.
  • Page 11: Step 14 Installing The Burner Components

    3. Repeat the above bake test or burner ignition test. 4. If the appliance still does not work, contact an authorized DACOR service company at (800) 772-7778. Do not attempt to repair the appliance yourself. DACOR is not responsible for service required to correct a faulty installation.
  • Page 12 NOTES Page 10...
  • Page 13 NOTES Page 11...
  • Page 14 NOTES Page 12...
  • Page 15 INSIDE BACK COVER THIS PAGE IS BLANK INTENSIONALLY...
  • Page 16 ��� ����� ������������� ��� � ��������������� ����� �������� ��������� ������ ����� ��������...