Niles MSU140 Installation & Operating Manual page 11

Infrared main system unit
Hide thumbs Also See for MSU140:
Table of Contents

Advertisement

I
N F R A R E D
STEP
3. Test for shorts and
interference.
4. Plug the flashers into the
flasher outputs. If you
need to extend the wire,
use a 2-conductor 16
gauge or larger (See
"Tech Tip" on page 6).
1
2
3
FLASHER OUTPUTS
Figure 7
M
A I N
DESCRIPTION
A) Reconnect the power supply. If the Power LED lights and the
IR Test LED stays off, unplug the connector from the power
socket and proceed to Step 4. The following LED conditions
show a fault:
•If Power LED is Off there is a short between +12v and GND
•If IR Test LED is On or flickers blue there is a short between
DATA and GND or interference is present.
Before you proceed to Step 4 consult the Troubleshooting
Section beginning on page 14.
Route the connecting wire to the IR Main System Unit.
Connect the 3.5mm plug into the jack labeled "Flasher
Output" on the MSU140. See (Figure 7).
BE SURE TO OBSERVE
PROPER POLARITY WHEN
EXTENDING THE FLASHER
WIRE.
The wire lead marked with a
gray stripe is positive (+);
4
the unmarked lead is nega-
tive (-).
S
U
Y S T E M
"TECH TIP"
Make all final connec-
tions to the MSU before
connecting the power
supply. This will avoid
potential damage
to components.
N I T
10

Advertisement

Table of Contents
loading

Table of Contents