Cabinet Side Removal

Lift hopper lid and remove screw. Remove the two screws
holding the back of the Cabinet Side to the chassis. Lift up
slightly to disengage the screws at the front and back. Pull off.
Installation is the reverse.
Fig. #15
C a b i n e t
S i d e
Screws

Cleaning the Flue Gas Passages

Cleaning the fl ue gas passage should be done at least once a
year or every one to two tons of pellets used.(50-100 bags)
Burning high ash pellets may require this cleaning to be done
more often.
Clean this passage only when the stove and ash are cold.

Cleaning the Firebox Passage

Remove the Burn-Pot and Liner as per previous cleaning section,
and use an appropriate vacuum cleaner to remove the loosened
ash from the fi rebox. Push on the top of the brick – this will kick
out the bottom edge. Pull the bottom of the Fire Brick towards
you. Drop the brick down once it clears the ledge.
Fig. #16
Using a ratchet with a 3/8" socket, remove the screws on both
sides of the Firebox Liner Fig.#17. Remove the Liner from the
fi rebox. Using a fi ltered shop vacuum, clean out all the ash in
the exhaust passages (fi g #18).
PELLET STOVES
Fig. #17
Firebox liner
screw
Fig. #18
Don't forget to clean up around the heat exchanger. Once the fl ue
passage is clear of ash build-up, reinstall the Firebox Liner.

Cleaning the Vent Pipe

Soot and Flyash – Formation and Need for Removal: The
products of combustion will contain small particles of fl yash
and/or soot. The Flyash and/or soot will collect in the exhaust
venting system and restrict the fl ow of the fl ue gases. The exhaust
venting system should be inspected at least once every year to
determine if cleaning is necessary. Sweep the pipe as needed.
A tee and clean-out in the vent system at the transition from
horizontal to vertical will make this cleaning easier.
Pacifi c Energy Fireplace Products recommends
having your stove inspected and cleaned by a
trained professional.
16
Firebox Passage -
Clean through here
PS45B 041113-24