DUAL INSTALLATIONS
2 5/16"
(5.9)
5 1/2"
ELEC.
(13.9)
9"
(22.9)
2 5/16"
83 1/2" min
84 1/2" max
(5.9)
(212.1-214.6)
Finished Opening
5 1/2"
ELEC.
(13.9)
9"
(22.9)
83 1/2" min
84 1/2" max
(212.1-214.6)
Finished Opening
WATER
3 1/2"
5"
(9.0)
(12.7)
WATER
25"
min
1"
(63.5)
3 1/2"
To wall
(2.5)
5"
(9.0)
(12.7)
DUAL PRODUCT CLEARANCES
25"
min
1"
(63.5)
To wall
(2.5)
130˚
Door swing
130˚
Door swing
B
ZIF360NHLH_ZIF360NHRH _ZIFP360NHLH_ZIFP360NHRH_ ZIFS360NHLH_ZIFS360NHRH
ZIR360NHLH_ZIR360NHRH_ZIRP360NHLH_ZIRP360NHRH_ZIRS360NHLH_ZIRS360NHRH
ZIF360NXLH_ZIF360NXRH _ZIFP360NXLH_ZIFP360NXRH_ ZIFS360NXLH_ZIFS360NXRH
36" Built-In All-Refrigerator
®
A
71 1/2"
(181.6)
Finished Width
24 3/16"
(61.4)
5 1/2"
ELEC.
(13.9)
9"
(22.9)
71 1/2"
(181.6)
Finished Width
24 3/16"
(61.4)
5 1/2"
ELEC.
(13.9)
9"
(22.9)
WATER
3 1/2"
5"
5"
(9.0)
5"
(12.7)
(12.7)
(12.7)
FRONT VIEW
WATER
25"
min
3 1/2"
(63.5)
To wall
5"
5"
(9.0)
5"
(12.7)
(12.7)
(12.7)
FRONT VIEW
25"
min
(63.5)
To wall
130˚
Door swing
5"
min
(12.7)
130˚
Door swing
5"
min
(12.7)
D
24"
(61.0)
Min. Cutout Depth
24"
(61.0)
Min. Cutout Depth
75 1/2"
(191.8 )
From floor
to bottom
of electrical
area
75 1/2"
3 1/2"
(191.8 )
(8.9)
From floor
to bottom
of electrical
area
SIDE VIEW
2" min
(5.1)
3 1/2"
(8.9)
SIDE VIEW
2" min
(5.1)
C
STANDARD INSTALLATION
NOTES
A A separate 115V, 60Hz, 15- or 20-amp
power supply is recommended for each
product.
Additional cutout width may be required when
side panels are used.
B In a side-by-side installation of a left-
and-right-hand door swing product, 1"
clearance between the units is required.
Order ZUG2: Custom panel unified grille kit for
one continuous grille panel.
C In a side-by-side installation with same
door swing, allow 2" minimum clearance
between the products to prevent the door
swing interference. Allow 15" minimum
to a wall to achieve full drawer extension
and pan removal. Additional clearances
are required when using custom panels
and handles.
3 1/2"
(8.9)
NOTE: ZUG2, ZUGSS2 or ZUGPP2 grille panel
W
kits will not fit this installation.
D In a side-by-side installation with right
and left door hinges together, allow 5"
minimum clearance between the two
15"
min
(38.1)
products to prevent one door from striking
To wall
the other. Additional clearances required
3 1/2"
when using custom panels and handles.
(8.9)
W
NOTE: ZUG2, ZUGSS2 or ZUGPP2 grille panel
kits will not fit this installation.
15"
min
(38.1)
To wall
Product Specification Revised 10/14