Date
2000-06
ELECTRICAL SUPPLY
The machines are wired for connection to a single-phase, 120V, 15A supply, with a heater power of 1400W,
giving a total power requirement of 1600W.
VALUES FOR WIRING DIAGRAMS
Resistance values at 68° F (+/-5°F), 20° C (+/-3°C)
(Values within +/- 10% is normal.)
AP
Drain pump
BB
Illumination switch
CP
Main pump
K D
Combi-dispenser
EL
Heating element
IV
Inlet valve
FL
Fan
LB
Door switch
LU
Door
N
Level switch
NTE
Level thermistor
P
Control unit
T
Thermostat
TB
Pushbutton switch
TTE
Temp. thermistor
WAX
Wax motor
VMG
Rinse ag sensor
OB
Overflow switch
Model D1796FI
(DW 95FI)
ELECTRICAL FUNCTIONS
120V, 60 Hz, 25.5 ohm
120 V, 60 Hz, Main = 10.5 ohm, Aux = 14.5 ohm
120 V, 0.31 ohm
120 V, 1400 W, 10 ohm
120 V, 9.93 K ohm (1-3, 2-4)
120 V, 0.25 K ohm
2.4 K ohm
19–25 K ohm
19–25 K ohm
1.5–3.0 K ohm