Asko D1796FI Service Manual page 3

Hide thumbs Also See for D1796FI:
Table of Contents

Advertisement

Date
2000-06
SETTING CHILD-SAFE START FUNCTION
The start function can be reprogrammed so that the button must be pressed in for 3 seconds to start the
programs. To do this, press S4 five times then press one of the following:
S5 to get a prolonged start function or
S4 to get a normal start function.
SETTING PUMP-OUT TIME
If it's necessary to reprogram the pump-out time, you can do so by pressing S3 five times then pressing
one of the following:
Press:
S3
S4
S5
S6
S7
SETTING INLET TIME
You can reprogram the inlet time on level controlled and time controlled inlets. To do this, press S5 five
times then press one of the following:
Press:
S3
S4
S5
S6
S7
S8
PROGRAMS
S = Pushbutton switch
to get an outlet time of:
20 seconds
25 seconds (factory setting)
35 seconds
45 seconds
85 seconds
to get an inlet time of:
45 seconds (factory setting)
56 seconds
68 seconds
90 seconds
113 seconds
180 seconds
Model D1796FI
(DW 95FI)
L = Indicator light