Roland GT-6 Service Notes page 15

Hide thumbs Also See for GT-6:
Table of Contents

Advertisement

fig.3
fig.4
To proceed to the next inspection, press the buttons in [EXIT] ->
[PARAMETER (>)] sequence.
10. EXT OD/DS
fig.LCD21
Confirm the following two points.
A) Using an oscilloscope, observe that a short wave is obtained from OUTPUT.
fig.10ext-1e
DSP
D/A
(Signal source)
DSP
A/D
D/A
(Rectangular waveform)
B) Insert an open plug in the RETURN jack and confirm that there is no output.
SEND
RETURN
OUTPUT
fig.10ext-2e
DSP
D/A
(Signal source)
DSP
A/D
D/A
(Rectangular waveform)
Note: Check both L(MONO) and R.
Also, when the OUTPUT jack is used for a single channel, the L and R signals
will be internally mixed, therefore, empty plugs must be inserted in the R
channel for L(MONO) channel measurement and in the L(MONO) channel for
R channel measurement, respectively.
OUTPUT Level Control : MAX
Oscilloscope : 1.0 V/DIV, 0.5 ms/DIV
Insert an empty plug in RETURN
fig.4
fig.2
To proeed to the next inspection, press the [EXIT] button.
GT-6(T)
SEND
(Cut off)
RETURN
OUTPUT