Contents 1. Introduction Features……………………………………………………….1 Specifications…………………………………………………3 2. Installation Installation and connection…………………………………..4 DIP Switch Setup……………………………………………...6 3. Operation Check points when power up…………………………………8 Control………………………………………………………….8 Camera and Lens control…………………………………….. 4. How to use OSD Menu Basic operation…………………………………………….10 Menu operation……………………………………………. 5. Trouble shooting………………………………………….25...
Features 1.1 Features ※ Camera Specifications: 1/4″ Interline Transfer CCD. CCD Sensor: Zoom Magnification: 10X Optical zoom, 10X Digital zoom. Day & Night function: The camera is configured to switch to the black and white mode automatically under low light conditions and at night with mechanical IR Cut filter for clear images.
Page 4
4 Patterns with 100 commands can be recorded and executed. This enables ● the camera to track a surveillance trajectory as closely as possible. 360° continuous scan. ● 360° intermittent scan. The camera will have seconds stop during each ● 90°turning.
1.2 Specifications Video Signal System NTSC 1/4〞Interline Transfer CCD Max. Pixels 811(H)X508(V) 795(H)X596(V) Horizontal Res 500TV Line(Color), 570 TV Line(B/W) S/N Ratio 50Db(AGC off) Zoom X10 Optical Zoom, X10 Digital Zoom Focal Length F1.8, f=3.8~38mm Camera Min. illumination 0.7Lux (Color),0.02Lux(B/W), F1.8, 50 IRE Day &...
Installation 2.1 Installation and Connection 2.1.1. Wall Mount (1) Connect Camera Plug the terminals into the bottom of the main unit, then, fix the main unit with screws supplier. (2) Bracket Installation Use the screws provided to secure the wall mount to the wall.
2.1.2.Ceiling Mount (1)Fix the main unit on the bracket. After wiring cables to terminals, plug the terminals into the bottom of main unit. Then, fix the main unit with screws provided (2)Install ceiling mount bracket on the ceiling using screws provided. 2.1.3 Cabling Connector Interface 2.2 DIP Switch Setup...
Page 8
Protocol: Pelco-D. 2.2.1 Camera ID Setup The range of ID is 0~255. Factory default of Camera ID is 1. ID number of camera is set using binary number. The number from 1~8 present 1, 2, 4, 8, 16, 32, 64, 128. For example, switch 1, 3, 5, 7 to “ON” position, the corresponding ID should be 1+4+16+64=85.
Page 9
Select the appropriate protocol with DIP switch combination. Switch State Protocol Pin No Pin 1 Pin 2 Pin 3 Pin 4 PELCO-P PELCO-D Protocol Auto Reserved 9600 2400 Baud rate 4800 9600...
Operation 3.1 Check points before operation Before power is connected, please check the cables carefully. The camera ID of the controller must be identical to that of the camera to be controlled. The camera ID can be checked in the System Information of OSD Menu.
position,,then, press ”Zoom, Lens, Iris” to adjust the pictures. Press “preset setup” to input number, then confirm by a press on setup key. ● Call Preset Press “Call Preset” key and input No of preset, the confirm by a press on ●...
3.3.2 Focus Adjust definition of the object of scene Press “Focus Far” key to shorten the distance of far scene. Press “Focus Near” key to shorten the distance of near scene. 3.3.3 Iris Press “Iris Open” key to adjust the brightness. Setup Menu After power up or restart, the present Protocol, Baud rate and Address will be displayed on the screen as below:...
MAIN MENU SYSTEM INFORMATION ADDR SETTING MOTION PATTERNS CAMERA CRUISE SETTING DISPLAY S ETUP RESTORE FACTORY DEFAULT REBOOT SYSTEM EXIT <SYSTEM INFORMATION>:Shows system information. <ADDR SETTING>:Select and setup Soft/Hard address. <MOTION>:Setup for motion related settings. <PATTERNS>:Setup for Patterns. <CAMERA>:Configure Camera related functions and data. <CRUISE SETTING>:Setup presets scan.
SYSTEM INFORMATION 2400,N,8,1 ADDRESS PROTOCOL PELCO-P PRESETS SOFTWARE VERSION V5.2 BACK EXIT <COM>:Shows current Baud rate. <ADDRESS>:Shows current Camera ID for PTZ control, 0~255. <PROTOCOL>:Shows current protocol for PTZ control. <PRESETS>:Shows the preset numbers. <SOFTWARE VERSION>:Shows current software version of camera. Notice: the system information can not be changed.
Page 15
4.2.3 Motion MOTION SET FRAME SCAN POWER UP PATTERN 4 PARK TIME PARK ACTION PATTERN 4 FRAME SCAN SPEED RANDOM SCAN SPEED BACK EXIT Motion setup is to setup preset and packing action function. SET FRAME SCAN:setup the LEFT/RIGHT extreme position between two presets.
Page 16
FRAME SCAN SET SCAN POSITION CLEAR FRAME SCAN BACK EXIT SET SCAN POSITION:Set up scan range between two positions (Left/Right extreme position). CLEAR FRAME SCAN:Deletes frame scan. 1. Set Scan Position (1)Move the cursor to <Set Scan Position> and enter below interface. SET FFRAME SCAN LEFT LIMIT POSITION IRIS OPEN TO CONTINUE...
Page 17
4.2.4 Patterns PATTERNS PATTERN NUMBER PROGRAM PATTERN CLEAR CURRENT PATTERN CLEAR ALL PATTERN BACK EXIT 4 Patterns are supported, please refer to below details: <PATTERN NUMBER>:Set Pattern number (1~4). <PROGRAM PATTERN>: Pattern scan program. <CLEAR CURRENT PATTERN>:Deletes data in current pattern. 1.Pattern Number (1)Move the cursor to “PATTERN NUMBER”...
Page 18
(3)Using keyboard or joystick of controller to edit pattern route and action, Max 100 actions, then press “Iris Open” to save. 4.2.5 Camera setup We are using Samsung SDM-100P camera to explain below operation. Main Menu Camera label White Balance Auto Auto Detection Focus...
Page 19
10,500K,)to ensure the most nature image effect. Auto Trace WB Auto Trace WB mode Outdoor Exit 2.2 Manual: Close auto WB, adjust Red and Blue level manually. Manual WB 30…|..………. Blue 41…..…|……. Exit Red adjust range: 0~100 Blue adjust range: 0~100 2.3 Auto BW : This mode is the most accurate and reliable for most places.
Page 20
Alarm : On/Off Region:1~4 Region Mode: On / Off 5.Focus Setup Focus Mode Auto Zoom trace mode Zoom trace speed Fast Digital Zoom Show Zoom Initial Zoom Position Lens Initialization Exit 1 Mode:Auto, Manual, One-off Auto focus. Press “Iris Open” to enter sub-menu.
Page 21
Using the direction keys to enlarge or downsize, press “ Iris/Open” key to back. (2) One-off Auto focus and Manual focus Adjustment: Setup Zoom Zoom In Zoom Out Near Back: Press “SET” key 2. Zoom trace mode: Manual Focus: Off. Auto and One-off Auto Focus: On / Off.
Page 22
Exposure Brightness 25….…|……. Iris Auto —— Shutter SSNR SENS-UP Exit Brightness range: 0~100. Iris:Auto/ Manual. Press “Iris Open” to enter into manual setup Manual Iris Iris 100….………| Exit If the number of iris is set to higher, the image will be brighter. Shutter mode: Flicker / Manual / Auto The shutter speed of Anti-flash is 1/100(NTSC)...
Page 23
Level Exit SSNR:High / Middle / Low / Off Enhances images by reducing noises when gain level of images too high. Sens-up: Manual / Off Adjust CCD exposure time. Auto mode setting:2X、4X、6X、8X、10X、12X、14X、16X、24X、32X、 64X、128X. Sens-up Sens up Exit 9 Additional menu: Additional menu User setup Privacy zone mask...
Page 24
(1 )User preset setup: On / Off User Preset User preset number No 1 User preset mode Save Clear Exit 预设未设置 8 user preset number, 1~8. User Preset mode: use direction keys to “On” and press “Iris/Open” to setup. User preset mode Focus Exposure Other...
Page 25
Other Camera Type Auto trace BW Motion Detection Privacy mask Day & Night Outer Horizontal flip Vertical flip Exit (2) Privacy mask Privacy mask Group selection Area selection Zone mode Color 50…|..………. 50…|..………. Bottom 104….…|……. Left 50…|.………. Right 98….……|…. Exit Group selection:1~ 8 Area selection: 1~4 zone / group Zone mode: On / Off...
Page 26
Color mode: suit for daytime. Auto mode: change day and night mode automatically according to the environment illumination. Auto 1 is faster than Auto 2. internal, unchangeable. (4) Synchronous mode: (5) Image adjustment. Image adjustment Freeze Horizontal flip Vertical flip Sharpness 50….…|…….
<Dwell Time (Sec)>: preset cruise dwell time, range:1~250 Sec. <Preset List>: 3 pages.30 presets. <1234567890>:preset position in the preset list. <110111 1111>:1 means the preset position corresponding to above preset list is elected to cruise list; 0 means overleap. <Back>:save the setup and back to main menu. <Exit>:Exit OSD menu.
Page 28
Maybe user setup wrong IP, Reset IP, Protocol and Baud Out of Protocol and Baud rate. rate. control after power up RS-485 cable reverse Check RS-485 connection connection or disconnection. cable. Video cable is bad connection Eliminate the bad connection Screen not stable Power is not enough.
Page 29
8. Do not install the camera close to air outlet of air condition. Camera lens will be misty because of water condensation under below conditions: Extreme temperature change. The room full of smoking or dust. 9. Do not locate the camera towards extremely bright objects such as sun and spotlight, as this may damage the CCD image sensor.