Planning Information
48"
Dual Fuel Ranges
(1219)
P L A N N I N G I N F O R M A T I O N
Refer to the illustrations and specifications for
overall dimensions, finished rough opening
dimensions and installation specifics.
IMPORTANT NOTE: Caution must be used in
planning the proper installation of the Wolf dual
fuel range to avoid fires or damage to adjacent
cabinetry or kitchen equipment. Please follow
the minimum clearances established in the
finished rough opening dimensions.
It is recommended that you use a Wolf Pro
wall or Pro island ventilation hood with the Wolf
dual fuel range.
The 48" (1219) dual fuel range requires a
240 V AC, 60 Hz, 50 amp fused electrical supply
to operate the electrical portions of the range.
Locate electrical and gas supply within the
shaded area shown in the Installation Specifica-
tions illustration on page 4.
Wolf dual fuel ranges are designed with a
terminal block on the rear of the range. The
terminal block allows for a 3-wire or 4-wire
installation. For a 4-wire installation, the ground
strap from the unit to the terminal block must be
cut. Two concentric knockouts on the base of
the unit, are provided to allow a certified electri-
cal contractor to wire the range directly to the
electrical supply. The terminal block will also
accept an appliance cord that is sized correctly
for the voltage and amperage of your range.
O V E R A L L D I M E N S I O N S
7
47
/
"
8
(1216)
OVERALL WIDTH
1
Dimensions may vary by + _
/
8
Dimensions in parentheses are in
millimeters unless otherwise specified.
7
35
36
/
"
8
(911)
(937)
OVERALL
HEIGHT TO
COOKING
SURFACE
" (3).
Wolf dual fuel ranges are designed to operate
on natural gas at 5" (127) WC (water column)
pressure or LP gas at 10" (254) WC pressure.
The maximum gas supply pressure to the regula-
tor should never exceed 14" (356) WC; .5 psi
(3.5 kPa).
Wolf recommends the use of a
commercial type flex hose; this is the minimum
size that may be used. All plumbing to the flex
3
hose must be
/
" (19) minimum I.D. pipe.
4
IMPORTANT NOTE: A separate external gas
shut-off valve must be located near the range in
an accessible location.
Wolf dual fuel ranges using natural gas
function up to an altitude of 8,000' (2438 m)
without any adjustment. Natural gas and LP gas
installations from 8,000' (2438 m) to 11,000'
(3353 m) need the high altitude kit. Contact your
Wolf dealer for details.
You must follow all National Electrical Code
and gas regulations. In addition, be aware of
local codes and ordinances when installing your
services.
Refer to the installation instructions shipped
with each Wolf product for detailed specifica-
tions.
1
29
/
"
2
(749)
OVERALL DEPTH
1
27
/
"
2
(699)
1
9
/
"
4
(235)
1
24
/
"
4
(616)
7
/
"
8
47"
(1194)
LEGS AND CASTERS ALLOW
1
2
/
"
8
(54) HEIGHT ADJUSTMENT
1
/
" (13) I.D.
2
7
56
/
"
8
(1445)
WITH 20"
RISER
7
46
/
"
8
(1191)
WITH 10"
RISER
7
41
/
"
8
(1064)
WITH 5"
RISER
2