Contrast Adjustment; Optical Adjustments - Sanyo PLC-XU111 Service Manual

Hide thumbs Also See for PLC-XU111:
Table of Contents

Advertisement

Optical Adjustments

Before taking optical adjustments below, remove the Cabinet Top following to the "Mechanical Disassembly".
Adjustments require a .0mm hex wrench and a slot screwdriver. When you adjust Integrator lens or Relay lens
adjustment, you need to disconnect FPC cables of LCD panels on the main board.
Optical adjustment requires a .0mm hex wrench and a slot screwdriver.
Note: Do not disconnect connectors on the main board, because the projector cannot turn on due to operate the
power failure protection.
WArNING : uSe uV rAdIAtIoN eYe ANd SKIN Pro-
tectIoN durING SerVIcING
cAutIoN: to prevent suffer of uV radiation, those adjustment must be
completed within 25 minutes.

Contrast adjustment

[Before Adjustment]
- Input a 100% of black raster signal.
1
A (Fig.1)
Loosen a screw
which you intend to adjust.
2
B
Adjust the slot
to obtain the darkest brightness on the screen by
using a slot screwdriver.
3
A
Tighten the screw
to fix the polarized glass mounting base.
Repeat steps 1 to 3 for remaining polarized glasses.
on the polarized glass mounting base
Slot B
Polarized glass
mounting base
-3-
A
Fig.1

Advertisement