Kozy-World KWP114 Owner's Operation And Installation Manual

Blue flame vent-free propane/lp gas space heater

Advertisement

Kozy-World
OWNER ' S OPERATION AND INSTALLATION MANUAL
KWP114
KWP116

Table of Contents

Important Safety Information.................................2
Product Features.....................................................3
Proper Ventilation & Fresh Air.................................4
.
Installation................................................................6
Operating Your Heater............................................10
Cleaning & Maintenance........................................13
Trouble Shooting....................................................14
Specifications..........................................................17
Parts List...................................................................19
World Marketing of America, Inc.
P.O. Box 192, Rt. 22 West
Mill Creek, PA 17060
KOZY WORLD PHONE NUMBER: (814) 643-1775
http://www.worldmkting.com
R
Save this manual for future reference.
WARNING: If the information in this
manual is not followed exactly, a f i r e o r
e x p l o s i o n
m a y
damage, personal injury, or loss of life.
WARNING: This is an unvented gas-fired
heater. It uses air (oxygen) f r o m t h e r o o m
i n
w h i c h
i t
i s installed. Provisions for
adequate combustion and ventilation air must
b e p r o v i d e d . R e f e r t o A i r F o r Combus-
tion and Ventilation section on page 4 of this
manual.
Do not store, or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
l
Do not try to light any appliance.
l
Do not touch any electrical switch; do not
use any phone in your building.
l
Immediately
call
neighbor's phone. Follow the gas supplier's
instructions.
l
If
you
cannot reach your gas supplier, call
the fire department.
Installation and service must be performed by a
q u a l i f i e d
i n s t a l l e r , s e r v i c e
supplier.
WA R N I N G :
adjustment, alteration, service or mainte-
nance can cause injury or property damage.
Refer to this manual for correct installation and
operational procedures. For assistance or
additional information consult a qualified
installer, service agency, or gas supplier.
This appliance may be installed in an aftermar-
ket*
permanently
(mobile) home, where not prohibited by local
codes.
This appliance is only for use with the type of
gas indicated on the rating plate. This
appliance is not convertible for use with other
gases.
*Aftermarket: Completion of sale, not for purpose of
resale, from the manufacturer.
BLUE FLAME VENT-FREE
PROPANE/LP GAS
SPACE HEATER
r e s u l t causing property
your gas supplier from a
a g e n c y
I m p r o p e r
i n s t a l l a t i o n ,
located, manufactured
o r
g a s

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KWP114 and is the answer not in the manual?

Questions and answers

Summary of Contents for Kozy-World KWP114

  • Page 1: Table Of Contents

    . R e f e r t o A i r F o r Combus- tion and Ventilation section on page 4 of this KWP114 manual. KWP116...
  • Page 2: Important Safety Information

    IMPORTANT 9. Do not use heater if any part Keep the appliance area clear has been under water. SAFETY INFORMATION a n d f r e e f r o m c o m b u s t i b l e Immediately call a qualified materials, gasoline, and other...
  • Page 3: Product Features

    PRODUCT FEATURES Figure1-Vent-Free Propane/LP Gas Heater SAFETY DEVICE LOCAL CODES A standard requirement for all vent-free room Install and use heater with care. Follow all local heaters. This heater has a pilot with an Oxygen codes. In the absence of local codes, use the Depletion Sensor(ODS) safety shutoff system.
  • Page 4: Proper Ventilation & Fresh Air

    Unusually Tight Construction Confined and FRESH AIR FOR The air that leaks around doors and Unconfined Space COMBUSTION AND windows may provide enough fresh The National Fuel Gas Code VENTILATION air for combustion and ventilation. ANS Z223.1 defines a confined However, in buildings of unusually space as a space whose volume WARNING: This heater...
  • Page 5: Air For Combustion And Ventilation

    3. Add the Btu/Hr of all fuel burning appliances in the space. Vent-free heater Btu/Hr Gas water heater* Btu/Hr Example: Gas furnace Btu/Hr Gas water heater 44,000 Btu/Hr Vented gas heater Btu/Hr Vent free heater 10,000 Btu/Hr Gas Fireplace logs Btu/Hr Total 54,000...
  • Page 6: Installation

    VENTILATION AIR Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or duels: You must provide two permanent openings: one within " of the ceiling and one within " of the floor. Connect these items directly to the outdoors or spaces open to the outdoors.
  • Page 7 INSTALLATION FASTENING HEATER TO WALL Attaching to Wall Stud: This method WARNING: Maintain the Mounting Bracket provides the strongest hold. Insert minimum clearances shown The mounting bracket is located mounting screws through mounting F i g u r e 4 . y o u c a n , back panel of heater (see bracket and into wall studs.
  • Page 8 INSTALLATION Attaching Mounting Bracket To IMPORTANT: Do not Wall hammer key! For thick walls Note: Wall anchors, mounting " (over 1/2 thick) or solid walls, screws, and spacers are in do not pop open wings. hardware package. The hardware package is provided with heater. Attaching to Wall Stud Method Figure 12 - Installing Bottom For attaching mounting bracket to...
  • Page 9 INSTALLATION CONNECTING TO GAS SUPPLY WARNING: A qualified service person must connect heater to gas supply. Follow all local codes. WARNING: This appliance " requires a 3/8 NPT (National Pipe T h r e a d ) i n l e t c o n n e c t i o n to the pressure regulator.
  • Page 10: Operating Your Heater

    INSTALLATION OPERATING YOUR HEATER CHECKING GAS Pressure Testing Heater Gas NON-THERMOSTAT MODEL CONNECTIONS Connections 1. Open equipment shutoff valve FOR YOUR SAFETY Test all gas piping WARNING: (see Figure 15). READ BEFORE LIGHTING and connections for leaks after Open propane/LP supply tank installing or servicing.
  • Page 11 OPERATING YOUR HEATER Manual Control Models Set control knob to desired TO TURN OFFn LIGHTING heating position. GAS TO APPLIANCE INSTRUCTIONS NOTE: Both HIGH and LOW are STOP! Read safety locked positions. You must press Shutting Off Heater information on the side of in control knob before turning it Turn control knob clockwise heater.
  • Page 12 OPERATING YOUR HEATER THERMOSTAT MODEL Wait five(5) minutes to clear CAUTION: Do not try to out any gas. Then smell for gas, adjust heating levels by using the including near the floor. If you FOR YOUR SAFETY equipment shutoff valve. “...
  • Page 13: Cleaning & Maintenance

    OPERATING HEATER BURNER FLAME PATTERN ODS/PILOT AND BURNER Continued Figure 23 shows a correct burner Use a vacuum cleaner, pres- flame pattern. Figure 24 shows an surized air, or a small, soft MANUAL LIGHTING incorrect burner flame pattern. If bristled brush to clean. PROCEDURE pilot flame pattern is incorrect, as Remove lower front panel (see...
  • Page 14: Troubleshooting

    TROUBLESHOOTING Note : troubleshooting CAUTION: Never use a wire, WARNING: Only a qualified items are listed in order of service person should service and needle, or similar object to clean operation. repair heater. ODS/pilot. This can damage ODS/pilot unit. OBSERVED PROBLEM POSSIBLE CAUSE REMEDY When ignitor button is pressed in,...
  • Page 15 TROUBLESHOOTING Continued POSSIBLE CAUSE REMEDY OBSERVED PROBLEM 1. Burner orifice is clogged. 1. Clean burner orifice (see Cleaning B u rn e r (s )does not l ight after and Maintenance Page 13) or ODS/pilot is lit. replace burner orifice. 2.
  • Page 16 TROUBLESHOOTING Continued WARNING: If you smell gas Shut off gas supply. Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • Page 17: Specifications

    SPECIFICATIONS KWP114 KWP116 Btu(available) 6,000/10,000 10,000 Propane/LP Only Propane/LP Only Gas Type Piezo Piezo Ignition " " Pressure Regulator setting W.C. W.C. Inlet Gas Pressure *(inches of water) " " Maximum " " Minimum Dimensions, Inches (HxWxD) × × ×...
  • Page 18: Parts List

    ILLUSTRATED PARTS LIST KWP114 ODS Pilot Assembly...
  • Page 19: Parts List

    PARTS LIST This list contains replaceable parts for your heater. When ordering replace- ment parts, follow the instructions listed under Replacement Parts on page17 KWP114 of this manual. KWP114 QTY. PART NO. DESCRIPTION MB10008 Cabinet Assembly MB09003 Lower Front Panel Assembly...
  • Page 20 ILLUSTRATED PARTS BREAKDOWN KWP116 ODS/Pilot Assembly...
  • Page 21 PARTS LIST This list contains replaceable parts for your heater. When ordering replace- KWP116 ment parts, follow the instructions listed under Replacement Parts on page17 of this manual. KWP116 DESCRIPTION PART NO. MB10007 Cabinet Assembly MB09003 Lower Front Panel Assembly MB11005 Reflector Unit ML086-03...

This manual is also suitable for:

Kwp116

Table of Contents

Save PDF