Indoor Unit

1.

Installing the mounting plate.

• The mounting plate should be installed on a wall which can support the weight of the indoor unit.
1) Temporarily secure the mounting plate to the wall, make sure that the panel is completely level, and mark the boring
points on the wall.
2) Secure the mounting plate to the wall with screws.
Recommended mounting plate retention spots and Dimensions
Recommended mounting
plate retention spots.
(5 spots in all)
2.

Boring a wall hole and installing wall embedded pipe.

• For walls containing metal frame or metal board, be sure to use a wall embed-
ded pipe and wall cover in the feed-through hole to prevent possible heat,
electrical shock, or fire.
• Be sure to caulk the gaps around the pipes with caulking material to prevent
water leakage.
1) Bore a feed-through hole of 65mm in the wall so it has a down slope toward
the outside.
2) Insert a wall pipe into the hole.
3) Insert a wall cover into wall pipe.
4) After completing refrigerant piping, wiring, and drain piping, caulk pipe hole
gap with putty.
■English
166
54.5
153.8
263
51.9
Liquid pipe end
Use tape measure
as shown.
Position the end
of a tape measure
at
.
184
181.7
800
Gas pipe end
Wall embedded pipe
(Field supply)
Through the wall
hole φ65mm
55.5
Drain hose position
Inside
Outside
Caulking
Wall hole cover
(Field supply)
Wall embedded pipe
(Field supply)
5