NOTES − All air data is measured external to unit with 1 in. (25 mm) cleanable filter (not furnished − field provided) in place. Also see Filter Air Resistance table.
Air volume based on bottom return air. Actual air volume may vary on side return air applications.
G50UHi−60C−110
External
External
Speed 1
Static
Factory Default
Pressure
Cool
in. w.g. Pa cfm L/s
Watts
0
0 2150 1015
915
0.1
25 2140 1010
935
0.2
50 2085 985
930
0.3
75 2085 985
1000
0.4
100 2055 970
1015
0.5
125 2010 950
1025
0.6
150 1950 920
1015
0.7
175 1900 895
1010
0.8
200 1845 870
1025
0.9
225 1740 820
980
NOTES − All air data is measured external to unit with 1 in. (25 mm) cleanable filter (not furnished − field provided) in place. Also see Filter Air Resistance table.
Air volume based on side return air. Actual air volume may vary on bottom return air applications.
G50UHi−60D−135
External
External
Speed 1
Static
Factory Default
Pressure
Cool
in. w.g. Pa cfm L/s
Watts
0
0 2160 1020
905
0.1
25 2165 1020
945
0.2
50 2115 995
935
0.3
75 2055 970
925
0.4
100 2090 985
1015
0.5
125 2065 975
1040
0.6
150 2020 955
1030
0.7
175 1965 925
1040
0.8
200 1910 900
1040
0.9
225 1805 850
975
NOTES − All air data is measured external to unit with 1 in. (25 mm) cleanable filter (not furnished − field provided) in place. Also see Filter Air Resistance table.
Air volume based on side return air. Actual air volume may vary on bottom return air applications.