Kenwood kdc-5090r/ry Service Manual page 6

Table of Contents

Advertisement

KDC-5090R/RY
QQ
MICROCOMPUTER'S TERMINAL DESCRIPTION
3 7 63 1515 0
Pin No.
Pin Name
39
CLKOUT
40
NC
41
NC
42
TYPE0
43
TYPE1
44
TYPE2
45
TYPE3
46
IC2TYPE0
47
IC2TYPE1
48
NC
49
NC
50
NC
51
NC
52
ILL-ON
53
M-MUTE L
54
M-MUTE R
55
BVDD
56
BVSS
TE
L 13942296513
57
M-RST
58
M-STOP
59
NC
60
LO/EJ
61
MOSW
62
NC
63
CD-SW3
64
NC
65
L-CE
66
NC
67
NC
68
NC
69
NC
70
AVCONT
71
AVDD
72
AVSS
73
AVREF
74
PHONE
75
NC(GND)
76
NC(GND)
www
77
SRT-SW2
.
78
SRT-SW1
79
NOISE
80
S-METER
81
R-DATA
6
I/O
Description
O
Internal system clock output
O
O
I
Destination type input terminal 0
I
Destination type input terminal 1
I
Destination type input terminal 2
I
Destination type input terminal 3
I
IC2 setting terminal
I
IC2 setting terminal
O
O
O
O
O
Illumination AVR on/off control output
I
Mute request (Lch) from CD MECHA. MI-COM. "Lo": Mute request
I
Mute request (Rch) from CD MECHA. MI-COM. "Lo": Mute request
-
Power supply connection terminal
-
Ground connection terminal
O
Reset output to CD MECHA. MI-COM.
O
Stop request to CD MECHA. MI-COM.
O
I/O CD MECHA. loading/Eject switching output "Lo": Loading, "Hi": Eject, "Hi-Z": Stop or Break
O
CD mechanism loading motor control output "Hi": CD loading/ eject action or Break, "Lo": other
O
I
Down & limit switch detection input
O
I/O CE output to LCD driver
O
O
O
O
O
A/D converter reference voltage control output
-
A/D converter power supply connection terminal Connected to BU 5V lines.
-
A/D, D/A converter ground connection terminal Connected to GND lines.
I
A/D converter reference voltage input terminal
I
PHONE detection input
I
I
x
ao
u163
I
SRT position detection input
y
i
I
SRT position detection input
I
FM noise detection input
I
S-meter input from F/E
I
Data input from the RDS decoder IC
2 9
8
Not used (N.C.)
Not used (N.C.)
Not used (N.C.)
"Lo": Initial value
"Lo": Initial value
Not used(N.C.)
Not used(N.C.)
Not used(N.C.)
Not used(N.C.)
"Hi": POWER ON mode except panel detached
or panel mask position
Connected to BU 5V lines.
Q Q
Connected to GND lines.
3
6 7
1 3
1 5
"Lo": Reset
"Lo": Stop mode, "Hi": Operation mode
Not used(N.C.)
Not used(N.C.)
"Hi": Chucking, "Lo": Pickup most inner position
Not used(N.C.)
Not used(N.C.)
Not used(N.C.)
Not used(N.C.)
Not used(N.C.)
"Hi": Active, Connected to AVREF terminal.
1V or less: TEL MUTE, 2.5V or greater: NAVI MUTE
Not used(pull down to GND lines)
Not used(pull down to GND lines)
Panel: (SW1, SW2)=(Hi, Hi)
co
Slide: (SW1, SW2)=(Hi, Lo)
.
Mask : (SW1, SW2)=(Lo, Lo)
Except RDS model: Not used (pull down to GND lines)
9 4
2 8
Processing Operation
0 5
8
2 9
9 4
2 8
m
9 9
9 9

Hide quick links: