Download Print this page
Avocent 2000 Release Notes
Avocent 2000 Release Notes

Avocent 2000 Release Notes

Universal management gateway
Hide thumbs Also See for 2000:

Advertisement

Quick Links

Avocent® Universal Management Gateway 2000/4000/6000 Appliance
This document outlines:
1. Update Instructions
2. Local Client Requirements
3. Features and Enhancements
4. UMIQ Module Support
5. Service Processor Support
6. Known Issues
===================================================================================
1. Update Instructions
===================================================================================
Please refer to the installer/user guide for detailed instructions on updating the Avocent® Universal
Management Gateway appliance.
If the current appliance version is older than 1.3.2.1, please update to appliance version 1.3.2.1 before
upgrading to the latest 2.x.x.x version. If your appliance(s) had already been upgraded multiple times using
version 2.x.x.x versions, and you see problems configuring the Service Processors, please contact Technical
Support for a recovery procedure.
IMPORTANT NOTE: When upgrading the appliance to 2.2.1.10 or later from 2.1.1.6 or earlier, please ensure
power is retained on the appliance for at least 60 minutes to allow the upgrade to complete. The appliance
upgrade process requires more time in this version as the FPGA is being upgraded. Also, please avoid rolling
back the version from 2.2.1.10 or later to 2.1.1.6 or earlier since there will be a FPGA downgrade procedure. If
there are any issues with upgrade or rollback, please contact Technical Support for additional assistance.
In order to have features listed in this release available through DSView™ 4 (v4.1.x) management software,
the Avocent® Universal Management Gateway appliance plug-in version 2.7.0.10 or later is required.
Older versions of the DSView™ software and the Avocent® Universal Management Gateway appliance 1.x
plug-in may work with this new firmware but could have limitations with the features or bug fixes of this release.
After upgrading the appliance to version 2.7.0.11, if KVM sessions launched via the DSView™ software display
an error message, resync the appliance with the DSView™ software and try again.
NOTE: If the Web interface Session times out while transferring the firmware upgrade file, the upgrade process
will be cancelled. If this occurs, lengthen or disable the Session Time-Out setting for the Admin user in the Web
interface before starting the upgrade.
===================================================================================
2. Local Client Requirements
===================================================================================
Software
Java (32-bit)
Adobe Flash
Internet Explorer
Firefox
Release Notes
Version 2.7.0.11
November 3, 2014
Version
Java 6 Update 45, Java 7 Update 60
11.3.300.262
8, 9, 10, 11
31
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the 2000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Avocent 2000

  • Page 1 =================================================================================== 1. Update Instructions =================================================================================== Please refer to the installer/user guide for detailed instructions on updating the Avocent® Universal Management Gateway appliance. If the current appliance version is older than 1.3.2.1, please update to appliance version 1.3.2.1 before upgrading to the latest 2.x.x.x version. If your appliance(s) had already been upgraded multiple times using version 2.x.x.x versions, and you see problems configuring the Service Processors, please contact Technical...
  • Page 2 This version also includes patches for the “Shellshock” vulnerabilities. Avocent recommends upgrading to this version or later to address the security risk. Please refer to the installer/user guide for a detailed list of features supported by the Avocent® Universal Management Gateway appliance.
  • Page 3 =================================================================================== 5. Service Processor Support =================================================================================== Tested Service Processors/Servers and Firmware Service Processor Firmware Version Cisco UCS-B Chassis and Blades 2.2(1c) Cisco UCS CIMC/Monolithic (C210) 1.4.3u Dell DRAC 4 (PowerEdge 1850) 1.75 (Build 06.03) Dell DRAC 5 (PowerEdge 2950) 1.65 (12.08.16) Dell DRAC/MC 1.6.9 Dell iDRAC blades (M600/M605/M805)
  • Page 4 Supported Service Processor Features Service Processor     G/S S*       IPMI 1.5  G*/S*    G/S S*           IPMI 2.0 IDRAC 7 (12G) ...
  • Page 5 When upgrading the appliance firmware, Service Processors previously added with IPMI 2.0 profiles will not be updated, even if the Service Processor is now a newly supported profile in the upgraded Avocent® Universal Management Gateway appliance release. If the full capabilities of the specific Service Processor are needed, delete and then re-add the Service Processor to use the newly defined profile.
  • Page 6 Access to the DRAC5 is possible with IE9.  The Dell DRAC5 Virtual Media applet fails when launched using the VGA console of the Avocent® Universal Management Gateway appliance. Please use the remote Web interface from a Windows client for these operations.
  • Page 7 The login process for the M1000e may take up to 20 seconds after proper username and credentials are presented, so it may take several seconds to access some features in the Avocent® Universal Management Gateway appliance Web interface. For example, displaying power information may take 15-20 seconds for an M1000e chassis.
  • Page 8  The HP iLO 2 Virtual Media applet fails when launched using the VGA console of the Avocent® Universal Management Gateway appliance. Please use the remote Web interface for these operations. HP iLO 3 ...
  • Page 9 Intermittent load failures of the vKVM and Virtual Media applets on RSA-II servers have been recorded when the JRE is allowed to keep temporary files on the computer. When using these vKVM and Virtual Media applications on RSA-II servers, Avocent recommends setting the JRE to disallow temporary file storage through the Java Control Panel.
  • Page 10: Known Issues

    ILOM servers must have their http service running to be properly discovered using the SP Auto-Discovery or IP Discovery features. If the http server is not running, the ILOM must be added to the Avocent® Universal Management Gateway appliance using the Manual SP Add feature.
  • Page 11 When rebooting the system, there is a small chance that the Restarting system message followed by machine restart will appear on the VGA Console. If this occurs, a power cycle of the Avocent® Universal Management Gateway appliance will be needed to recover the KVM appliance.
  • Page 12 ‘,’.  The Avocent® Universal Management Gateway 2000 appliance does not update the Event Viewer Log page when switching to a different page and back to the Event Viewer Log page. The Event Viewer Log page will reload when the Next button is clicked to advance to the next page of Event Log, then the Prev button is clicked to return to the original Event Log page.
  • Page 13  Occasionally, the port number of a UMIQ module is not updated in the Avocent® Universal Management Gateway appliance Web interface when moving the UMIQ module from one port or the other. The UMIQ module may need to be completely unplugged from the appliance and server, then reattached. If DSView™...
  • Page 14 RW permissions, but then will only allow RO operations.  If both serially-connected (such as the Avocent Power Management PM 1000, PM 2000 and PM 3000 Power Distribution Units) and IP-connected (such as Liebert® MPH/MPX) PDUs are connected to the Avocent®...
  • Page 15 Emerson, Emerson Network Power and the Emerson Network Power logo are trademarks or service marks of Emerson Electric Co. Avocent, the Avocent logo, DSView and Trellis are trademarks or service marks of Avocent Corporation. Liebert is a trademark or service mark of Liebert Corporation.

This manual is also suitable for:

40006000