DIMENTIONAL CARACTERISTICS LENGHT 2050 mm WIDTH 1270 mm HEIGHT 1530 mm N°SWEPING BRUSHES SIDE SWEEP BRUSH DIMENTION ( diameter ) 500 mm MAIN BRUSH DIMENTIONS ( lenght ; diameter ) 1000 mm ; 330 mm WORKING WIDHT WITH RH HAND SIDE BRUSH 1250 mm WORKING WIDHT WITH RH, LH (OPTIONAL) SIDE BRUSHES 1500 mm...
Page 3
PERFORMANCE FORWARD SPEED 0÷10 Km/h REVERSE SPEED 0÷10 Km/h MAX CLIMB GRADIENT MAX CLIMB GRADIENT FOR U TURN 5% A 3 Km/h CLEANED FOR HOUR m²/h 12500 m²/h ECOLOGICAL CHARACTERISTICS NOISE LEVEL AT OPERATOR CAR 83 Db OPERATOR POSITION VIBRATIONS LOWER AT 2,5 M/s²...
THIS MACHINE CAN BE CORRECTLY USED AS FOLLOWS: The sweeper to be used on flat surfaces or slopes up to 13% and to sweep floors with any lining, excluding carpets. THIS MACHINE IS NOT SUITABLE FOR ANY OTHER USE AND PARTICULARLY: it cannot be used as a tractor, on slopes beyond 13% or as a vehicle to transport people.
Page 5
FIG. 2 TECHNICAL DATA LABEL RECAPITULATION Ing. O. Fiorentini S.r.l. MADE 50030 Piancaldoli (Fi) IN ITALY Mod. S.N. S 38B 1997 1587 4500...
Page 6
In case of goods to be returned for warranty replacement, it is necessary to have a written acceptance from FIORENTINI technical department before sending them. All defective parts must be carefully packed in order to avoid further damages during transport.
Before using the machine, instruct all operators to read the chapter “SAFETY STANDARDS” (enclosed MANUFACTURER RESPONSABILITIES The manufacturer FIORENTINI is not responsible for any inconvenients, failures, accidents, etc. due to the non-acquaitance (or non-fulfilment) of the prescriptions contained in this manual. The same applies to change’s execution, modifications, and/or to the installation of accessory not preliminarly...
Page 8
in compliance with its destination, by observing the safety and prevention standards according to the prescriptions contained in the instruction and maintenance handbook. Remove (or let remove) immedi- ately any failures which could compromise the safety. The machine is exclusively designated to be used as a scrubber;...
Page 9
All six month, check the efficiency of the safety devices, the inspection should be performed by qualified personnel of FIORENTINI s.r.l. or authorized by it. To grant the efficiency of the safety devices, the machine should be overhauled by a technician of FIORENTINI every 5 years.
FIG. 5 DESCRIPTION The UBF 38 power sweeper has been designed to perform a complete cycle of industrial and urban cleaning. The sweeping action is carried out by one or more side brushes which convery the waste towards the centre of the machine, where a central brush, a roller, sweeps it “into the hopper”. The dust is suked up and controlled by a turbine.
INSTALLING THE BATTERIES Install the batteries on the proper compartment. Inspect batteries carefully before installing, thus making sure that there are no cracks in the cases. Never add electrolyte if batteries have been in use for one week or longer. For positive connections of the batteries, the surfaces which get in contact with them should be clean.
MACHINE START-UP AND SET-UP If the scrubber is connected to the battery charger (having finished the charge operation), detach the battery charger plug from the socket (located on the machine) coming from the battery (fig.). Then, connect the plug of the machine to this latter (fig.). Close the battery cover again. Before operating the sweeper, check the oil level inside the hydraulic unit tank.
Page 15
ADJUSTMENT OF DUST SEALING GASKETS The dust sealing gaskets should skim the soil. To adjust them, loosen the fastening screws and lower the gasket support. When finished, fasten the screws again. FIG. 9 1) closing flap jack 2) container lifting jack HOW TO RELEASE THE MACHINE To tow the machine it is better to release the hydrostatic transmission turning the lever in the open position.
MAINTENANCE MAINTENANCE SCHEDULE WEEKLY Check the brush condition. Check if the suction filters are clean. MONTHLY Check the brush wear state. It should not exceed half of its height and should freely slide within the brush-holder. Check that the air-intakes are not obstructed and that the fan is working properly. EVERY SIX MONTHS Check the carbons condition on each motor.
In any case, before re-operating a battery which is inactive for a long period of time, recharge it and check for a correct level of the electrolyte. SUCTION SYSTEM The suction system includes a fan controlled by the hydraulic motor. It is used to suck the dust produced by brush rotation.
FIG. 13 1) filter shaker motor 2) connector CAUTION Any maintenance or repair not included in the standard maintenance operations should be performed by skilled technicians authorised by company Ing. O. FIORENTINI.
Page 19
HYDRAULIC SYSTEM SCHEME 1 ELECTRIC MOTOR 15 CONTAINER LEVER 2 VARIABLE CAPACITY PUMP 16 CENTRAL BRUSH LEVER 3 FIXED PUMP 17 HYDRAULIC MOTOR RIGHT BRUSH 4 FIXED PUMP FOR HYDRAULIC DRIVE 18 HYDRAULIC MOTOR LEFT BRUSH 6 HYDRAULIC OIL EXHAUST COLLECTOR 19 HYDRAULIC MOTOR CENTRAL BRUSH 7 HYDRAULI OIL RADIATOR 20 OPENING CONTAINER HYRAULIC JACK...
Page 20
Serial no. Nr. de serie Data di spedizione Date of shipment Date de spedition ING. O. FIORENTINI s.r.l. Distribuito da: “ The Best in floor machines ” FILIALI: 20132 MILANO - Fax. 02/2592779 Via Palmanova 211/a - Tel02/27207783 - 2564810 00155 ROMA - Fax.