Settings Page; Disk Page - Sony PWS-100PR1 Operation Manual

Production control station
Hide thumbs Also See for PWS-100PR1:
Table of Contents

Advertisement

Available languages

Available languages

Error/Warning
Displays errors and warnings that occur in the system.
The following major error messages are displayed.
ID
Message
0101,
POWER
0102
SUPPLY [A/B]
ERROR
0111 to
FAN [1-5]
0115
ERROR
0121 to
HDD [1-12]
012C
ERROR
0131
HIGH
TEMPERATURE
0132
HIGH
TEMPERATURE
0133
HIGH
TEMPERATURE
0134
HIGH
TEMPERATURE
0141
LOW BATTERY
0151
DIO-98 INITIAL
ERROR
0152
SMBUS ERROR An error occurred on the
The following major warning messages are displayed.
ID
Message
0201,
POWER
0202
SUPPLY [A/B]
WARNING
0211 to
FAN [1-5]
0215
WARNING
0221 to
HDD [1-12]
022C
WARNING
0238
LOW
TEMPERATURE
a) Only if an HDD is installed in the unit

Settings Page

This page is used to change system settings.
Menu Settings
001 LINE LED
Specifies whether the front panel LED is on/off.
• ON: LED is lit (default).
Description
A power supply error was
detected in the power supply
unit.
A fan failure was detected.
a)
An HDD error was detected.
The temperature inside the unit
(CPU) is high.
The temperature inside the unit
(MB board) is high.
The temperature inside the unit
a)
(storage) is high.
The temperature inside the unit
(MSQ-S321) is high.
The backup battery voltage is
low.
Initialization of the DIO-98
board failed.
SMBUS I/F of the MB-1204
board.
Description
The speed of the power supply
fan has dropped.
The speed of the fan has
dropped.
The number of HDD read/write
a)
errors is increasing.
The temperature inside the unit
is too low.
If an HDD is installed in the
unit, the HDD throughput
cannot be guaranteed if the
temperature becomes too low.
• OFF: LED is not lit.
002 REDUNDANT PSU
Specifies whether an optional power supply unit is
installed for power supply redundancy.
• ON: Installed.
• OFF: Not installed (default).
Click the [Save] button to apply the settings.
SNMP Settings
Specifies SNMP settings.
• Host IP Address: Specifies the IP address of the SNMP
host. The default setting is "127.0.0.1."
• Trap IP Address: Specifies the IP address of the trap
destination.
• Community Name: Specifies the SNMP community
name (up to 16 characters). The default setting is
"public."
• SYS CONTACT: Specifies contact information (up to
255 characters) for the system administrator.
• SYS NAME: Specifies the system admin name (up to
255 characters).
• SYS LOCATION: Specifies the system location (up to
255 characters).
Click the [Save] button to apply the settings.

Disk Page

This page displays the status of the HDDs, if any HDDs are
installed in the system.
Disk Status
The following items are displayed for each HDD.
• Physical drive number and capacity
• Logical drive number when used in a RAID structure
• RAID type
• Disk status
The disk status is displayed using the drive number
background color.
Background color Status
Green
Normal
Red
A warning has been issued.
Gray
An error has occurred. Or an HDD
has spun down.
You can then remove the HDD.
Black
The HDD is not inserted.
[Spin Down] button
Spins down the selected HDD so that it can be removed.