7.13. Remove the SS-Board
1. Unlock the cable clampers to free the cable.
2. Disconnect the connectors (SS11, SS12, SS24, SS33
and SS35).
3. Remove a short-jumper connector SS34 and re-use for
new SS-Board.
4. Disconnect the flexible cables (SS53, SS55 and SS56).
5. Remove the screws (×6
7.14. Remove the SS2-Board
1. Disconnect the connector (SS24) and disconnect the flex-
ible cable (SS58).
2. Remove the screws (×2
) and remove the SS-Board.
) and remove the SS2-Board.
7.15. Remove the Stand brackets
1. Remove the Plasma panel section from the servicing
stand and lay on a fiat surface such as a table (covered)
with the Plasma panel surface facing downward.
2. Remove the Stand brackets (L, R) fastening screws
(×5
each) and remove the Stand brackets (L, R).
7.16. Remove the D-Board
1. Remove the A-Board unit. (See section 7.7.)
2. Disconnect the connectors (D3, D5 and D25).
3. Disconnect the flexible cables (D20, D31, D32 and D33).
4. Remove the screws (×4
21