Table 6
CW - Cooling Capacity 13,000
Power Supply
Compressor
Volt — 1–60
Volt
Min
RLA
LRA
115V
104
10.8
53
208/
197
7.4
33
230V
265V
240
6.0
28
Table 7
CM / WM - Cooling Capacity 15,000
Power Supply
Volt — 1–60
Volt
Min
208/
230V
Models
CM &
WM
197
208/
230V
Model
CM only
265V
240
The Right Fit for Comfort
• Installation, Operation, and Maintenance Manual •
Electrical Specifications
electrical specifications
Indoor Fan
Electric Heat
Motor
FLA
Hp
Htr #
Volt
1.4
0.09
N/A
N/A
0
N/A
208
2
230
208
3
0.6
0.08
230
208
4
230
208
5
230
0
N/A
2
265
0.67
0.08
3
265
4
265
electrical specifications
Indoor Fan
Compressor
Motor
RLA
LRA
FLA
Hp
Htr #
7.4
33
0.6
0.08
6.0
28
0.67
0.08
Water Source Console Units
IMPORTANT
Unit Electrical Ratings
W
HA
TCA
THA
N/A
N/A
13.8
N/A
N/A
N/A
N/A
1636
7.9
8.5
2000
8.7
9.3
2454
11.8
12.4
8.0
3000
13
13.6
3271
15.7
16.3
4000
17.4
18.0
4089
19.7
20.3
5000
21.7
22.3
N/A
N/A
N/A
2655
10
10.7
6.7
3983
15
15.7
5310
20
20.7
Electric Heat
Volt
W
HA
0
N/A
N/A
N/A
208
1636
7.9
2
230
2000
8.7
208
2454
11.8
3
230
3000
13.0
208
3271
15.7
4
230
4000
17.4
208
4089
19.7
5
230
5000
21.7
0
N/A
N/A
N/A
2
265
2655
10
3
265
3983
15
4
265
5310
20
24
MCA
MOCP
Plug
16.5
25
5-20P
9.9
15
6–15P
10.4
15
6–15P
11.5
15.3
20
6–20P
16.9
20.3
25
6-30P
22.3
25.2
30
6-30P
27.8
8.2
15
13.2
7-20P
19.5
20
25.7
30
7-30P
Unit Electrical Ratings
TCA
THA
MCA
MOCP
Plug
N/A
9.9
15
6–15P
8.5
10.4
15
6–15P
9.3
11.5
12.4
15.3
20
6–20P
8.0
13.6
16.9
16.3
20.3
25
6-30P
18.0
22.3
20.3
25.2
30
6-30P
22.3
27.8
N/A
8.2
15
7-20P
10.7
13.2
15
6.7
7-20P
15.7
19.5
20
20.7
25.7
30
7-30P
P/N 240008071, Rev. B [112309]