FILTER KIT

(12 PACK)
are provided to adjust airflow supplied to meet individual instal-
lation needs for such things as noise, comfort, and humidity
removal. (See Fig. 19, D as indicated.)
ON/OFF DELAY - SELECT DESIRED TIME DELAY PROFILE
Four motor operation delay profiles are provided to customize and
enhance system operation. (See Fig. 19, E as indicated)
Selection options are:
1. The standard 90 sec off delay (Factory setting) at 100 percent
airflow.
2. No delay option used for servicing unit or when a thermostat
is utilized to perform delay functions.
3. A 30 sec on delay with no airflow/90 sec off delay at 100
percent airflow profile is used when it is desirable to allow
system coils time to heat-up/cool-down in conjunction with
the airflow.
4. ENH, enhanced selection, provides a 30 sec on delay with no
airflow/ plus 150 sec at 70 percent airflow/ no off delay for
added comfort. This profile will minimize cold blow in heat
Table 1—Filter Kits
PART NUMBER
KFAFK0212MED
KFAFK0312LRG
KFAFK0412XXL
SEC1
SEC2
J1
TM
EASY SELECT
AUX HEAT KW/CFM
0-30
0-20
0-10
0-5
J2
1075
875
725
625
VIO
AC/HP SIZE
036
030
024
018
BLU
SYSTEM TYPE
AC
HP-COMFORT
HP-EFF
ORN
AC/HP CFM ADJUST
NOM
LO
HI
BLK
ON/OFF DELAY
0
30
0
ENH
90
90
0
WHT
CONTINUOUS FAN
AUX1
HUM1
LO
MED
HI
YEL
YEL
AUX2
HUM2
CEBD430226-01B CESS430226-01B
24VAC
GRY
HEATER/MOTOR
12-PIN MATE-N-LOCK
ELECTRIC HEAT CONNECTOR
Fig. 17—PCB Wiring Arrangement
10
D
H
R
W
1
W
2
Y
1
Y/Y
2
G
O
C
pump operation and could enhance system efficiency.
CONTINUOUS FAN - SELECT DESIRED FAN SPEED WHEN
THERMOSTAT IS SET ON CONTINUOUS FAN
1. LO speed - factory setting, 50 percent cooling mode airflow.
2. MED speed - move connector to MED, 65 percent cooling
mode airflow.
3. HI speed - move connector of HI, 100 percent cooling mode
airflow. (See Fig. 19, F as indicated.)

LOW-VOLTAGE CIRCUIT FUSING AND REFERENCE

The low-voltage circuit is fused by a board-mounted 5-amp
automotive fuse placed in series with the transformer SEC2 and
the R circuit. The C circuit of the transformer is referenced to
chassis ground through a printed circuit run at SEC1 connected to
metal standoff marked with ground symbol.
BASIC FAN COIL CONFIGURATION
The following basic configuration of the fan coil will provide ARI
rated performance of the heat pump:
SIZE USED WITH
002
003, 005
006
A95275