Section 1: Kt-100 Features - Kantech kt-100 Installation Manual

Door controller
Hide thumbs Also See for kt-100:
Table of Contents

Advertisement

S e c t i o n 1 : K T - 1 0 0 F e a t u r e s
The KT-100 Door Controller contains all the intelligence and
necessary inputs/outputs to manage one door; it is also easily
linked to a network controlling up to 32 doors.
The KT-100 Door Controller features include:
Speed selection.
The KT-100 automatically detects the loop
communication speed as set at the system workstation.
Trouble reporting.
The KT-100 constantly supervises
power supply conditions and reports "Low power" status to the
system. The power output is protected against short-circuits and
surges by a self-resetting PTC. The locking device is supervised
for short to ground or open circuits. It also monitors all the
equipment for any failure or tampering. Any abnormal
condition is reported to the software.
Input power
Dimensions (H•W•D)
Weight
Operating temperatures / Humidity range
Reader types
Control relay outputs
Monitored input zones
Points maximum wiring
Door strike output
Auxiliary outputs (LED, BUZ)
Reader power output
Communication port
Communication speed
Reader communication interface
Flash memory
RAM memory
Backup battery
Network autonomy
Certifications / Listing
Downloadable firmware.
stored in the controller's flash memory; it can be easily updated
from the system's workstation without changing the memory
chips.
Integration with a client alarm system.
Controller allows the ability to arm/disarm any client alarm
system. In addition, interfacing with an external alarm system
allows the installer to assign the appropriate user permission to
arm or disarm the external alarm system. Optionally, adding a
keypad will increase the security as cardholders will be required
to enter a valid code in addition to presenting a valid card at the
door reader. For details about using the KT-100 Controller to
interface another alarm panel, refer to "Using the KT-100 with
an external alarm panel" on page 12.
Tec h n i c a l S p e c i f i c a t i o n s
9.5 to 14 VDC / 50mA + accessories (Max. 750 mA)
11.4 cm x 7.0 cm x 3 cm (4.5"; 2.75"; 1.25"), mounted
cal box without any additional enclosure
110 g (0.22 lbs)
From 2
C to 40
C (35
F to110
0
0
0
Wiegand, proximity, bar code, magnetic, integrated keypad and others
2 relay outputs, 12VDC, 25mA max/each. Open collector to ground (use form C relays such as
Kantech/KT-RM1 if needed)
2 control relay outputs, 30VAC/DC, 50mA (max) each. Two Opto-isolated contacts per relay
4 monitored input zones, NO/NC, with or without end of line resistors
600 meters (2,000 feet) - (AWG #22)
1 form C output, 12VDC, 250 mA max, supervised
2 outputs, open NPN collector for door access and status 25mA max, 12 DC each
5VDC @ 150mA protected
RS-485
From 1200 to 115,200 baud (automatic detection)
ANSI, SIA, ABA clock and data, Wiegand 5 conductor
64 K
128 K
Lithium battery, up to 10 years retention (data and RTC operation)
Distributed data and processing
FCC Part 15, Class B
K T - 1 0 0
I n s t a l l a t i o n
The firmware program is
in a standard single gang electri-
F) / 0-95% (non-condensing)
0
M a n u a l
The KT-100
3

Advertisement

Table of Contents
loading

Table of Contents