11 Measurements and Adjustments
This chapter explains the measuring equipment, the JIG connection, and the PC setting method necessary for the measurement in
Troubleshooting Guide (P.29)
11.1. Equipment Required
• Digital multi-meter (DMM): it must be able to measure voltage and current.
• Oscilloscope.
• Frequency counter: It must be precise enough to measure intervals of 1 Hz (precision; ±4 ppm)
Hewlett Packard, 53131A is recommended.
• DECT tester: Rohde & Schwarz, CMD 60 is recommended.
This equipment may be useful in order to precisely adjust like a mass production.
11.2. The Setting Method of JIG (Base Unit)
This section explains the PC setting to use command required in Check Point (Base Unit) (P.41).
<Preparation>
• Serial JIG cable: PQZZ1CD300E*
• PC which runs in DOS mode
• Batch file CD-ROM for setting: PNZZPRW120
11.2.1. Connections
Connect the AC adaptor to DC-JACK (base unit).
Connect the JIG Cable GND (black) to GND.
Connect the JIG Cable RX (red) to URX and TX (yellow) to UTX.
To Serial Port
(COM port 1*)
PC
Note:
*: COM port names may vary depending on what your PC calls it.
Note:
1
AC adaptor
3
URX (red)
3
UTX
UTX (yellow)
2
GND (black)
52
*: If you have the JIG Cable for TCD500 series
(PQZZ1CD505E),
change
resistance. Then you can use it as a JIG Cable for both
TCD300 and TCD500 series. (It is an upper compatible JIG
Cable.)
Resistor
Old value (kΩ)
R2
22
R3
22
R4
22
R7
4.7
URX
GND
Base unit P. C. board
the
following
values
New value (kΩ)
3.3
3.3
4.7
10