Antiice; Starter; 1-27. Transmission; Rotor - Bell BHT-206L3-FM-1 LongRanger-III Flight Manual

Table of Contents

Advertisement

BHT-206L3-FM-1
DOT APPROVED
1-25.
ANTI-ICE
The maximum
ambient
temperature
for use
I
of engine
anti-ice
is
4.4°C (40°F).
ENGINE
ANTI-ICING
shall
be ON for flight
I
in visible
moisture
in temperature
below
4.4°C (40°F).
1-26.
STARTER
Limit starter
energize
time to the following:
External
Power Start Battery
Start
40 Seconds
ON
60 Seconds
ON
30 Seconds
OFF
60 Seconds
OFF
40 Seconds
ON
60 Seconds
ON
30 Seconds
OFF
60 Seconds
OFF
40 Seconds
ON
60 Seconds
ON
30 Minutes
OFF
30 Minutes
OFF
1-27. TRANSMISSION
1-26.
TRANSMISSION
OIL
PRESSURE
Minimum
Continuous
operation
Maximum
30 PSI
40 to 70 PSI
70 PSI
1-29.
TRANSMISSION
OIL
TEMPERATURE
Continuous
operation
15 to 110°C
Maximum
110°C
1-30.
ROTOR
1-31.
ROTOR RPM -
POWER ON
Minimum
transient
(Do not exceed
5
seconds)
-
95%
Minimum
Continuous
operation
Maximum
continuous
Maximum
transient
during
low power
descent.
(Do not
exceed
6 minutes
above
100%.)
97%
97 to 100%
100%
103%
1-32.
ROTOR
RPM -
POWER
OFF
Minimum
90%
Maximum
107%
1-33.
FUEL AND OIL
1-34.
FUEL
Turbine
fuel ASTM-D-1655,
Type B, or MIL-
T-5624,
Grade
JP-4,
may
be used
at all
ambient
temperatures.
1-10