Youjie YJ-HF500 User Manual

Youjie YJ-HF500 User Manual

Area-imaging scanner
Table of Contents

Advertisement

YJ-HF500
Area-Imaging Scanner
User's Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the YJ-HF500 and is the answer not in the manual?

Questions and answers

Summary of Contents for Youjie YJ-HF500

  • Page 1 YJ-HF500 Area-Imaging Scanner User’s Guide...
  • Page 2 Youjie reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult Youjie to determine whether any such changes have been made. The infor- mation in this publication does not represent a commitment on the part of Youjie.
  • Page 3: Table Of Contents

    Table of Contents Chapter 1 - Getting Started About This Manual .......................1-1 Unpacking Your Device .......................1-1 Connecting the Device ......................1-1 Connecting with USB .....................1-1 Connecting with RS232 Serial Port................1-2 Reading Techniques ......................1-3 Menu Bar Code Security Settings ..................1-3 Setting Custom Defaults ......................1-3 Resetting the Custom Defaults ....................1-4 Chapter 2 - Programming the Interface Introduction ..........................2-1...
  • Page 4 Chapter 3 - Input/Output Settings Power Up Beeper ........................ 3-1 Beep on BEL Character....................... 3-1 Good Read and Error Indicators..................3-1 Beeper – Good Read..................... 3-1 Beeper Volume – Good Read..................3-2 Beeper Pitch – Good Read.................... 3-2 Beeper Pitch – Error ...................... 3-2 Beeper Duration –...
  • Page 5 Intercharacter, Interfunction, and Intermessage Delays............4-3 Intercharacter Delay ...................... 4-3 User Specified Intercharacter Delay ................4-3 Interfunction Delay......................4-4 Intermessage Delay....................... 4-4 Chapter 5 - Data Formatting Data Format Editor Introduction ..................5-1 Add a Data Format ......................5-1 Other Programming Selections..................5-2 Terminal ID Table ........................
  • Page 6 EAN/JAN-8 ........................6-25 MSI ............................ 6-27 GS1 DataBar Omnidirectional ................... 6-29 GS1 DataBar Limited......................6-29 GS1 DataBar Expanded ....................6-30 Codablock A ........................6-30 Codablock F ........................6-31 PDF417 ..........................6-32 MacroPDF417 ........................6-32 MicroPDF417........................6-33 GS1 Composite Codes...................... 6-33 UPC/EAN Version......................
  • Page 7 Query Commands ....................... 9-1 Responses........................9-2 Resetting the Custom Defaults.................... 9-3 Menu Commands ........................ 9-3 Chapter 10 - Product Specifications YJ-HF500 Scanner Product Specifications ............... 10-1 Standard Cable Pinouts..................... 10-2 Serial Output........................ 10-2 USB ..........................10-2 Chapter 11 - Maintenance and Troubleshooting Repairs ..........................
  • Page 9: Chapter 1 - Getting Started

    Youjie bar code scanners are factory programmed for the most common terminal and communications settings. If you need to change these settings, programming is accomplished by scanning the bar codes in this guide.
  • Page 10: Connecting With Rs232 Serial Port

    2. Connect the appropriate interface cable to the device. Note: For the scanner to work properly, you must have the correct cable for your type of terminal/computer. YJ-HF500 RS232 Serial Port Connection: Note: The power supply must be ordered separately, if needed.
  • Page 11: Reading Techniques

    Menu Bar Code Security Settings Youjie scanners are programmed by scanning menu bar codes or by sending serial commands to the scanner. If you want to restrict the ability to scan menu codes, you can use the Menu Bar Code Security settings. Please contact the nearest technical...
  • Page 12: Resetting The Custom Defaults

    You may have a series of custom settings and want to correct a single setting. To do so, just scan the new setting to overwrite the old one. For example, if you had previously saved the setting for Beeper Volume at Low to your custom defaults, and decide you want the beeper volume set to High, just scan the Set Custom Defaults bar code, then scan the Beeper Volume High menu code, and then Save Custom Defaults.
  • Page 13: Chapter 2 - Programming The Interface

    Programming the Interface Introduction This chapter describes how to program your system for the desired interface. Programming the Interface - Plug and Play Plug and Play bar codes provide instant scanner set up for commonly used interfaces. Note: After you scan one of the codes, power cycle the host terminal to have the interface in effect. RS232 Serial Port The RS232 Interface bar code is used when connecting to the serial port of a PC or terminal.
  • Page 14: Usb Pc Or Macintosh Keyboard

    Scan the following code to program the scanner to emulate a regular RS232-based COM Port. If you are using a Microsoft® Windows® PC, you will need to download a driver from the Youjie website (www.youjieaidc.com). The driver will use the next available COM Port number.
  • Page 15: Verifone ® Ruby Terminal Default Settings

    Bioptic Aux Port Configuration Scan the following Plug and Play code to program the scanner for a Youjie bioptic scanner auxiliary port configuration. This bar code sets the baud rate to 38400 bps and the data format to 8 data bits, no parity, 1 stop bit.
  • Page 16: Ncr Bioptic Aux Port Configuration

    NCR Bioptic Aux Port Configuration Scan the following Plug and Play code to program the scanner for an NCR bioptic scanner auxiliary port configuration. The fol- lowing prefixes are programmed for each symbology: Symbology Prefix Symbology Prefix UPC-A Interleaved 2 of 5 UPC-E Code 128 GS1 DataBar...
  • Page 17: Wincor Nixdorf Rs232 Mode A

    Wincor Nixdorf RS232 Mode A Scan the following Plug and Play code to program the scanner for a Wincor Nixdorf RS232 Mode A terminal. This bar code sets the baud rate to 9600 bps and the data format to 8 data bits, odd parity, 1 stop bit. The following prefixes are programmed for each symbology: Symbology Prefix...
  • Page 18 Keyboard Countries (Continued) Belgium Bosnia Brazil Brazil (MS) Bulgaria (Cyrillic) Bulgaria (Latin) Canada (French legacy) Canada (French) Canada (Multilingual) Croatia Czech 2 - 6...
  • Page 19 Keyboard Countries (Continued) Czech (Programmers) Czech (QWERTY) Czech (QWERTZ) Denmark Dutch (Netherlands) Estonia Faroese Finland France Gaelic Germany 2 - 7...
  • Page 20 Keyboard Countries (Continued) Greek Greek (220 Latin) Greek (220) Greek (319 Latin) Greek (319) Greek (Latin) Greek (MS) Greek (Polytonic) Hebrew Hungarian (101 key) Hungary 2 - 8...
  • Page 21 Keyboard Countries (Continued) Iceland Irish Italian (142) Italy Japan ASCII Kazakh Kyrgyz (Cyrillic) Latin America Latvia Latvia (QWERTY) Lithuania 2 - 9...
  • Page 22 Keyboard Countries (Continued) Lithuania (IBM) Macedonia Malta Mongolian (Cyrillic) Norway Poland Polish (214) Polish (Programmers) Portugal Romania Russia 2 - 10...
  • Page 23 Keyboard Countries (Continued) Russian (MS) Russian (Typewriter) Serbia (Cyrillic) Serbia (Latin) Slovakia Slovakia (QWERTY) Slovakia (QWERTZ) Slovenia Spain Spanish variation 2 - 11...
  • Page 24 Keyboard Countries (Continued) Sweden Switzerland (French) Switzerland (German) Tatar Turkey F Turkey Q Ukrainian United Kingdom United States (Dvorak) United States (Dvorak left) United Stated (Dvorak right) 2 - 12...
  • Page 25: Keyboard Style

    Keyboard Countries (Continued) United States (International) Uzbek (Cyrillic) Keyboard Style This programs keyboard styles, such as Caps Lock and Shift Lock. If you have used Keyboard Conversion settings, they will override any of the following Keyboard Style settings. Default = Regular. Regular is used when you normally have the Caps Lock key off.
  • Page 26: Keyboard Conversion

    Emulate External Keyboard should be scanned if you do not have an external keyboard (IBM AT or equivalent). Emulate External Keyboard Note: After scanning the Emulate External Keyboard bar code, you must power cycle your computer. Keyboard Conversion Alphabetic keyboard characters can be forced to be all upper case or all lowercase. So if you have the following bar code: “abc569GK,”...
  • Page 27 Control + ASCII Mode On: The scanner sends key combinations for ASCII control characters for values 00-1F. Windows is the preferred mode. All keyboard country codes are supported. DOS mode is a legacy mode, and it does not support all key- board country codes.
  • Page 28: Rs232 Modifiers

    Automatic Direct Connect Mode: This selection can be used if you have an IBM AT style terminal and the system is dropping characters. Default = Off. Automatic Direct Connect Mode * Automatic Direct Connect Mode Off RS232 Modifiers RS232 Baud Rate Baud Rate sends the data from the scanner to the terminal at the specified rate.
  • Page 29: Rs232 Word Length: Data Bits, Stop Bits, And Parity

    38400 57,600 115,200 RS232 Word Length: Data Bits, Stop Bits, and Parity Data Bits sets the word length at 7 or 8 bits of data per character. If an application requires only ASCII Hex characters 0 through 7F decimal (text, digits, and punctuation), select 7 data bits. For applications that require use of the full ASCII set, select 8 data bits per character.
  • Page 30: Rs232 Receiver Time-Out

    8 Data, 1 Stop, Parity Even * 8 Data, 1 Stop, Parity None 8 Data, 1 Stop, Parity Odd RS232 Receiver Time-Out The unit stays awake to receive data until the RS232 Receiver Time-Out expires. When an RS232 receiver is sleeping, a character may be sent to wake up the receiver and reset the time-out.
  • Page 31: Rs232 Timeout

    * RTS/CTS Off RS232 Timeout When using Flow Control with Timeout, you must program the length of the delay you want to wait for CTS from the host. Set the length (in milliseconds) for a timeout by scanning the bar code below, then setting the timeout (from 1-5100 millisec- onds) by scanning digits from the inside back cover, then scanning Save.
  • Page 32: Scanner To Bioptic Communication

    Scanner to Bioptic Communication The following settings are used to set up communication between Youjie scanners and bioptic scanners. Note: The scanner’s baud rate must be set to 38400 and the RS232 timeout must be set to 3000 in order to communicate with a bioptic scanner.
  • Page 33: Chapter 3 - Input/Output Settings

    Input/Output Settings Power Up Beeper The scanner can be programmed to beep when it’s powered up. Scan the Off bar code(s) if you don’t want a power up beep. Default = Power Up Beeper On - Scanner. Power Up Beeper Off - Scanner * Power Up Beeper On - Scanner...
  • Page 34: Beeper Volume - Good Read

    Beeper Volume – Good Read The beeper volume codes modify the volume of the beep the scanner emits on a good read. Default = High. Medium * High Beeper Pitch – Good Read The beeper pitch codes modify the pitch (frequency) of the beep the scanner emits on a good read. Default = Medium. Low (1600 Hz) * Medium (2700 Hz) High (4200 Hz)
  • Page 35: Beeper Duration - Good Read

    High (4200 Hz) Beeper Duration – Good Read The beeper duration codes modify the length of the beep the scanner emits on a good read. Default = Normal. * Normal Beep Short Beep Short Beep LED – Good Read The LED indicator can be programmed On or Off in response to a good read. Default = On. * LED - Good Read On LED - Good Read Off Number of Beeps –...
  • Page 36: Good Read Delay

    Good Read Delay This sets the minimum amount of time before the scanner can read another bar code. Default = 0 ms (No Delay). * No Delay Short Delay (500 ms) Medium Delay (1,000 ms) Long Delay (1,500 ms) User-Specified Good Read Delay If you want to set your own length for the good read delay, scan the bar code below, then set the delay (from 0-30,000 milli- seconds) by scanning digits from the inside back cover, then scanning Save.
  • Page 37: Idle Illumination - Presentation Mode

    Medium Medium High * High Idle Illumination - Presentation Mode Scan one of the bar codes below to set the LED illumination for the scanner when it is in an idle state in Presentation Mode. Default = High. Note: If you use one of the lower Idle Illumination settings, and there is not enough ambient light, the scanner may have difficulty detecting when a bar code is presented to it.
  • Page 38: Presentation Centering

    Presentation Centering Use Presentation Centering to narrow the scanner’s field of view when it is in the stand to make sure the scanner reads only those bar codes intended by the user. For instance, if multiple codes are placed closely together, Presentation Center- ing will insure that only the desired codes are read.
  • Page 39: Poor Quality Codes

    Top of Presentation Centering Window Bottom of Presentation Centering Window Left of Presentation Centering Window Right of Presentation Centering Window Poor Quality Codes Poor Quality PDF Codes This setting improves the scanner’s ability to read damaged or badly printed PDF codes by combining information from mul- tiple images.
  • Page 40: 2D Reread Delay

    Reread Delay This sets the time period before the scanner can read the same bar code a second time. Setting a reread delay protects against accidental rereads of the same bar code. Longer delays are effective in minimizing accidental rereads. Use shorter delays in applications where repetitive bar code scanning is required.
  • Page 41: Character Activation Mode

    Long (3000ms) Extra Long (4000ms) Character Activation Mode You may use a character sent from the host to trigger the scanner to begin scanning. When the activation character is received, the scanner continues scanning until either the Character Activation Laser Timeout (page 3-10), the deactivation character is received (see Deactivation Character...
  • Page 42: Character Activation Laser Timeout

    Character Activation Laser Timeout You can set a timeout for the length of time the laser remains on and attempting to decode bar codes when using Character Activation Mode. Set the length (in milliseconds) for a timeout by scanning the following bar code, then setting the timeout (from 1-65535 milliseconds) by scanning digits from the Programming Chart, then scanning Save.
  • Page 43: Aimer Mode

    Aimer Mode This feature allows you to turn the aimer on and off. When the Interlaced bar code is scanned, the aimer is interlaced with the illumination LEDs. Default = Interlaced. * Interlaced Centering Use Centering to narrow the scanner’s field of view to make sure that when the scanner is hand-held, it reads only those bar codes intended by the user.
  • Page 44: Video Reverse

    Scan Centering On, then scan one of the following bar codes to change the top, bottom, left, or right of the centering window. Then scan the percent you want to shift the centering window using digits on the inside back cover of this manual. Scan Save. Default Centering = 40% for Top and Left, 60% for Bottom and Right.
  • Page 45: Working Orientation

    * Video Reverse Off Working Orientation Some bar codes are direction-sensitive. For example, KIX codes and OCR can misread when scanned sideways or upside down. Use the working orientation settings if your direction-sensitive codes will not usually be presented upright to the scanner. Default = Upright.
  • Page 46 3 - 14...
  • Page 47: Chapter 4 - Data Editing

    Data Editing Prefix/Suffix Overview When a bar code is scanned, additional information is sent to the host computer along with the bar code data. This group of bar code data and additional, user-defined data is called a “message string.” The selections in this section are used to build the user-defined data into the message string.
  • Page 48: To Clear One Or All Prefixes Or Suffixes

    Example: Add a Tab Suffix to All Symbologies Step 1. Scan Add Suffix. Step 2. Scan 9, 9 from the Programming Chart inside the back cover of this manual to apply this suffix to all symbologies. Step 3. Scan 0, 9 from the Programming Chart inside the back cover of this manual.
  • Page 49: Function Code Transmit

    Clear One Suffix Clear All Suffixes Function Code Transmit When this selection is enabled and function codes are contained within the scanned data, the scanner transmits the function code to the terminal. Charts of these function codes are provided in Supported Interface Keys starting on page...
  • Page 50: Interfunction Delay

    Next, scan the Character to Trigger Delay bar code, then the 2-digit hex value for a printable character to trigger the delay (see Lower ASCII Reference Table on page A-4). Delay Length Character to Trigger Delay To remove this delay, scan the Delay Length bar code, and set the number of delays to 0. Scan the Save bar code using Programming Chart inside the back cover of this manual.
  • Page 51: Chapter 5 - Data Formatting

    Data Formatting Data Format Editor Introduction You may use the Data Format Editor to change the scanner’s output. For example, you can use the Data Format Editor to insert characters at certain points in bar code data as it is scanned. The selections in the following pages are used only if you wish to alter the output.
  • Page 52: Other Programming Selections

    from the Programming Chart inside the back cover of this manual. (Note: 50 characters is entered as 0050. 9999 is a universal number, indicating all lengths.) Step 6. Editor Commands Refer to Data Format Editor Commands (page 5-3). Scan the symbols that represent the command you want to enter. Step 7.
  • Page 53: Terminal Id Table

    Terminal ID Table Terminal Model(s) Terminal ID PC keyboard (HID) Mac Keyboard PC Keyboard (Japanese) Serial (COM driver required) HID POS USB SurePOS Handheld USB SurePOS Tabletop Serial RS232 TTL RS232 True Data Format Editor Commands Send Commands Send all characters F1 Include in the output message all of the characters from the input message, starting from current cursor position, followed by an insert character.
  • Page 54: Move Commands

    Send all characters up to a particular character F3 Include in the output message all characters from the input message, starting with the character at the current cursor position and continuing to, but not including, the search character “ss,” followed by an insert character. The cursor is moved forward to the “ss”...
  • Page 55: Search Commands

    Move the cursor forward 3 characters, then send the rest of the bar code data from the bar code above. End with a carriage return. Command string: F503F10D F5 is the “Move the cursor forward a number of characters” command 03 is the number of characters to move the cursor F1 is the “Send all characters”...
  • Page 56: Miscellaneous Commands

    44 is the hex value for “D” F1 is the “Send all characters” command 0D is the hex value for a CR The data is output as: DEFGHIJ <CR> Search backward for a character F9 Search the input message backward for “xx” character from the current cursor position, leaving the cursor pointing to the “xx”...
  • Page 57 FB is the “Suppress characters” command 01 is the number of character types to be suppressed 20 is the hex value for a space F1 is the “Send all characters” command 0D is the hex value for a CR The data is output as: 34567890 <CR>...
  • Page 58: Data Formatter

    Command string: ECF10D EC is the “Check for a number” command F1 is the “Send all characters” command 0D is the hex value for a CR If this bar code is read, the next data format, if there is one, will be used on the data. If there is no other format, the format fails and the raw data is output as AB1234.
  • Page 59: Primary/Alternate Data Formats

    Data Format Required, Keep Prefix/Suffix Scanned data is modified according to your data format, and prefixes and suffixes are transmitted. Any data that does not match your data format requirements generates an error tone and the data in that bar code is not transmitted. Default = Data Formatter On, Not Required, Keep Prefix/Suffix.
  • Page 60 5 - 10...
  • Page 61: All Symbologies

    Symbologies This programming section contains the following menu selections. Refer to Chapter 9 for settings and defaults. • All Symbologies • GS1-128 • Aztec Code • Interleaved 2 of 5 • China Post (Hong Kong 2 of 5) • Korea Post •...
  • Page 62: Codabar

    EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15Max. length = 15 For a value other than the minimum and maximum message length defaults, scan the bar codes included in the explanation of the symbology, then scan the digit value of the message length and Save bar codes on the Programming Chart inside the back...
  • Page 63: Codabar Concatenation

    Validate Modulo 16, but Don’t Transmit Validate Modulo 16 and Transmit Codabar Concatenation Codabar supports symbol concatenation. When you enable concatenation, the scanner looks for a Codabar symbol having a “D” start character, adjacent to a symbol having a “D” stop character. In this case the two messages are concatenated into one with the “D”...
  • Page 64: Code 39

    Code 39 < Default All Code 39 Settings > Code 39 On/Off * On Code 39 Start/Stop Characters Start/Stop characters identify the leading and trailing ends of the bar code. You may either transmit, or not transmit Start/ Stop characters. Default = Don’t Transmit. Transmit * Don’t Transmit Code 39 Check Character...
  • Page 65: Code 32 Pharmaceutical (Paraf)

    Code 39 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information. Minimum and Maximum lengths = 0-48. Minimum Default = 0, Maximum Default = 48. Minimum Message Length Maximum Message Length Code 39 Append This function allows the scanner to append the data from several Code 39 bar codes together before transmitting them to...
  • Page 66: Full Ascii

    Full ASCII If Full ASCII Code 39 decoding is enabled, certain character pairs within the bar code symbol will be interpreted as a single character. For example: $V will be decoded as the ASCII character SYN, and /C will be decoded as the ASCII character #. Default = Off.
  • Page 67: Interleaved 2 Of 5

    Interleaved 2 of 5 < Default All Interleaved 2 of 5 Settings > Interleaved 2 of 5 On/Off * On Check Digit No Check Digit indicates that the scanner reads and transmits bar code data with or without a check digit. When Check Digit is set to Validate, but Don’t Transmit, the unit only reads Interleaved 2 of 5 bar codes printed with a check digit, but will not transmit the check digit with the scanned data.
  • Page 68: Nec 2 Of 5

    Maximum Message Length NEC 2 of 5 < Default All NEC 2 of 5 Settings > NEC 2 of 5 On/Off * On Check Digit No Check Digit indicates that the scanner reads and transmits bar code data with or without a check digit. When Check Digit is set to Validate, but Don’t Transmit, the unit only reads NEC 2 of 5 bar codes printed with a check digit, but will not transmit the check digit with the scanned data.
  • Page 69: Code 93

    NEC 2 of 5 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 80. Minimum Message Length Maximum Message Length Code 93...
  • Page 70: Code 93 Code Page

    Code 93 Append This function allows the scanner to append the data from several Code 93 bar codes together before transmitting them to the host computer. When this function is enabled, the scanner stores those Code 93 bar codes that start with a space (excluding the start and stop symbols), and does not immediately transmit the data.
  • Page 71: Straight 2 Of 5 Industrial (Three-Bar Start/Stop)

    Straight 2 of 5 Industrial (three-bar start/stop) <Default All Straight 2 of 5 Industrial Settings> Straight 2 of 5 Industrial On/Off * Off Straight 2 of 5 Industrial Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information.
  • Page 72: Straight 2 Of 5 Iata (Two-Bar Start/Stop)

    Straight 2 of 5 IATA (two-bar start/stop) <Default All Straight 2 of 5 IATA Settings> Straight 2 of 5 IATA On/Off * Off Straight 2 of 5 IATA Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information.
  • Page 73: Matrix 2 Of 5

    Matrix 2 of 5 <Default All Matrix 2 of 5 Settings> Matrix 2 of 5 On/Off * Off Matrix 2 of 5 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information.
  • Page 74: Check Digits Required

    Code 11 <Default All Code 11 Settings> Code 11 On/Off * Off Check Digits Required This option sets whether 1 or 2 check digits are required with Code 11 bar codes. Default = Two Check Digits. One Check Digit * Two Check Digits Code 11 Message Length Scan the bar codes below to change the message length.
  • Page 75: Code 128

    Code 128 <Default All Code 128 Settings> Code 128 On/Off * On ISBT 128 Concatenation In 1994 the International Society of Blood Transfusion (ISBT) ratified a standard for communicating critical blood informa- tion in a uniform manner. The use of ISBT formats requires a paid license. The ISBT 128 Application Specification describes 1) the critical data elements for labeling blood products, 2) the current recommendation to use Code 128 due to its high degree of security and its space-efficient design, 3) a variation of Code 128 that supports concatenation of neigh- boring symbols, and 4) the standard layout for bar codes on a blood product label.
  • Page 76: Code 128 Code Page

    Code 128 Append This function allows the scanner to append the data from several Code 128 bar codes together before transmitting them to the host computer. When the scanner encounters a Code 128 bar code with the append trigger character(s), it buffers Code 128 bar codes until it reads a Code 128 bar code that does not have the append trigger.
  • Page 77: Gs1-128

    GS1-128 <Default All GS1-128 Settings> GS1-128 On/Off * On GS1-128 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 1, Maximum Default = 80. Minimum Message Length Maximum Message Length UPC-A...
  • Page 78 UPC-A Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On. * On UPC-A Number System The numeric system digit of a U.P.C. symbol is normally transmitted at the beginning of the scanned data, but the unit can be programmed so it will not transmit it.
  • Page 79: Upc-A/Ean-13 With Extended Coupon Code

    UPC-A Addenda Required When Required is scanned, the scanner will only read UPC-A bar codes that have addenda. You must then turn on a 2 or 5 digit addenda listed on page 6-18. Default = Not Required. Required * Not Required UPC-A Addenda Separator When this feature is on, there is a space between the data from the bar code and the data from the addenda.
  • Page 80: Coupon Gs1 Databar Output

    Coupon GS1 DataBar Output If you scan coupons that have both UPC and GS1 DataBar codes, you may wish to scan and output only the data from the GS1 DataBar code. Scan the GS1 Output On code below to scan and output only the GS1 DataBar code data. Default = GS1 Out- put Off.
  • Page 81 UPC-E0 Addenda Required When Required is scanned, the scanner will only read UPC-E bar codes that have addenda. Default = Not Required. Required * Not Required UPC-E0 Addenda Separator When this feature is On, there is a space between the data from the bar code and the data from the addenda. When turned Off, there is no space.
  • Page 82: Upc-E1

    UPC-E0 Addenda This selection adds 2 or 5 digits to the end of all scanned UPC-E data. Default = Off for both 2 Digit and 5 Digit Addenda. 2 Digit Addenda On * 2 Digit Addenda Off 5 Digit Addenda On * 5 Digit Addenda Off UPC-E1 Most U.P.C.
  • Page 83: Ean/Jan-13

    EAN/JAN-13 <Default All EAN/JAN Settings> EAN/JAN-13 On/Off * On Convert UPC-A to EAN-13 When UPC-A Converted to EAN-13 is selected, UPC-A bar codes are converted to 13 digit EAN-13 codes by adding a zero to the front. When Do not Convert UPC-A is selected, UPC-A codes are read as UPC-A. UPC-A Converted to EAN-13 * Do not Convert UPC-A EAN/JAN-13 Check Digit...
  • Page 84 EAN/JAN-13 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN/JAN-13 data. Default = Off for both 2 Digit and 5 Digit Addenda. 2 Digit Addenda On * 2 Digit Addenda Off 5 Digit Addenda On * 5 Digit Addenda Off EAN/JAN-13 Addenda Required When Required is scanned, the scanner will only read EAN/JAN-13 bar codes that have addenda.
  • Page 85: Isbn Translate

    ISBN Translate When On is scanned, EAN-13 Bookland symbols are translated into their equivalent ISBN number format. Default = Off. * Off EAN/JAN-8 <Default All EAN/JAN-8 Settings> EAN/JAN-8 On/Off * On EAN/JAN-8 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On.
  • Page 86 EAN/JAN-8 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN/JAN-8 data. Default = Off for both 2 Digit and 5 Digit Addenda. 2 Digit Addenda On * 2 Digit Addenda Off 5 Digit Addenda On * 5 Digit Addenda Off EAN/JAN-8 Addenda Required When Required is scanned, the scanner will only read EAN/JAN-8 bar codes that have addenda.
  • Page 87: Msi

    <Default All MSI Settings> MSI On/Off * Off MSI Check Character Different types of check characters are used with MSI bar codes. You can program the scanner to read MSI bar codes with Type 10 check characters. Default = Validate Type 10, but Don’t Transmit. When Check Character is set to Validate Type 10/11 and Transmit, the scanner will only read MSI bar codes printed with the specified type check character(s), and will transmit the character(s) at the end of the scanned data.
  • Page 88: Msi Message Length

    Validate Type 11 then Type 10 Character and Transmit Disable MSI Check Characters MSI Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information. Minimum and Maximum lengths = 4-48. Minimum Default = 4, Maximum Default = 48. Minimum Message Length Maximum Message Length 6 - 28...
  • Page 89: Gs1 Databar Omnidirectional

    GS1 DataBar Omnidirectional < Default All GS1 DataBar Omnidirectional Settings > GS1 DataBar Omnidirectional On/Off * On GS1 DataBar Limited < Default All GS1 DataBar Limited Settings > GS1 DataBar Limited On/Off * On 6 - 29...
  • Page 90: Gs1 Databar Expanded

    GS1 DataBar Expanded < Default All GS1 DataBar Expanded Settings > GS1 DataBar Expanded On/Off * On GS1 DataBar Expanded Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information.
  • Page 91: Codablock F

    Codablock A Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information. Minimum and Maximum lengths = 1-600. Minimum Default = 1, Maximum Default = 600. Minimum Message Length Maximum Message Length Codablock F <Default All Codablock F Settings>...
  • Page 92: Pdf417

    PDF417 < Default All PDF417 Settings > PDF417 On/Off * On PDF417 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information. Minimum and Maximum lengths = 1-2750. Minimum Default = 1, Maximum Default = 2750. Minimum Message Length Maximum Message Length MacroPDF417...
  • Page 93: Micropdf417

    MicroPDF417 < Default All MicroPDF417 Settings > MicroPDF417 On/Off * Off MicroPDF417 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information. Minimum and Maximum lengths = 1-366. Minimum Default = 1, Maximum Default = 366. Minimum Message Length Maximum Message Length GS1 Composite Codes...
  • Page 94: Upc/Ean Version

    UPC/EAN Version Scan the UPC/EAN Version On bar code to decode GS1 Composite symbols that have a U.P.C. or an EAN linear compo- nent. (This does not affect GS1 Composite symbols with a GS1-128 or GS1 linear component.) Default = UPC/EAN Ver- sion Off.
  • Page 95: Tcif Linked Code 39 (Tlc39)

    GS1 DataBar Emulation GS1 Code Expansion Off EAN8 to EAN13 Conversion * GS1 Emulation Off TCIF Linked Code 39 (TLC39) This code is a composite code since it has a Code 39 linear component and a MicroPDF417 stacked code component. All bar code readers are capable of reading the Code 39 linear component.
  • Page 96: Qr Code Page

    QR Code Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information. Minimum and Maximum lengths = 1-7089. Minimum Default = 1, Maximum Default = 7089. Minimum Message Length Maximum Message Length QR Code Append This function allows the scanner to append the data from several QR Code bar codes together before transmitting them to...
  • Page 97: Data Matrix

    Data Matrix < Default All Data Matrix Settings > Data Matrix On/Off * On Data Matrix Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information. Minimum and Maximum lengths = 1-3116. Minimum Default = 1, Maximum Default = 3116. Minimum Message Length Maximum Message Length Data Matrix Append...
  • Page 98: Maxicode

    codes were created (see ISO 2022/ISO 646 Character Replacements on page A-7), and scan the value and the Save bar code from the Programming Chart on the inside the back cover of this manual. The data characters should then appear properly.
  • Page 99: Aztec Code

    Aztec Code < Default All Aztec Code Settings > Aztec Code On/Off * On Aztec Code Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for additional information. Minimum and Maximum lengths = 1-3832. Minimum Default = 1, Maximum Default = 3832. Minimum Message Length Maximum Message Length Aztec Append...
  • Page 100: Chinese Sensible (Han Xin) Code

    codes were created (see ISO 2022/ISO 646 Character Replacements on page A-7), and scan the value and the Save bar code from the Programming Chart on the inside the back cover of this manual. The data characters should then appear properly.
  • Page 101: Postal Codes - 2D

    Postal Codes - 2D The following lists the possible 2D postal codes, and 2D postal code combinations that are allowed. Only one 2D postal code selection can be active at a time. If you scan a second 2D postal code selection, the first selection is overwritten. Default = 2D Postal Codes Off.
  • Page 102: Combination 2D Postal Codes

    Postnet On Also see Postnet Check Digit, page 6-44. Postnet with B and B’ Fields On InfoMail On Combination 2D Postal Codes: InfoMail and British Post On Intelligent Mail Bar Code and Postnet with B and B’ Fields On Postnet and Postal-4i On Postnet and Intelligent Mail Bar Code On...
  • Page 103 Planet Code and Postnet with B and B’ Fields On Planet Code and Postal-4i On Planet Code and Intelligent Mail Bar Code On Planet Code, Postnet, and Postal-4i On Planet Code, Postnet, and Intelligent Mail Bar Code On Planet Code, Postal-4i, and Intelligent Mail Bar Code On Postnet,...
  • Page 104 Planet Code, Postal-4i, Intelligent Mail Bar Code, and Postnet On Planet Code, Postal-4i, Intelligent Mail Bar Code, and Postnet with B and B’ Fields On Planet Code Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of Planet Code data. Default = Don’t Transmit.
  • Page 105: Postal Codes - Linear

    Combination C and N Tables causes the field to be interpreted using either the C or N Tables. * Bar Output Numeric N Table Alphanumeric C Table Combination C and N Tables Postal Codes - Linear The following lists linear postal codes. Any combination of linear postal code selections can be active at a time. China Post (Hong Kong 2 of 5) <Default All China Post (Hong Kong 2 of 5) Settings>...
  • Page 106: Korea Post

    Maximum Message Length Korea Post <Default All Korea Post Settings> Korea Post * Off Korea Post Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-1) for addi- tional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 48. Minimum Message Length Maximum Message Length Korea Post Check Digit...
  • Page 107: Keyboard Function Relationships

    Interface Keys Keyboard Function Relationships The following Keyboard Function Code, Hex/ASCII Value, and Full ASCII “CTRL”+ relationships apply to all terminals that can be used with the scanner. Refer to page 2-15 enable Control + X (Control + ASCII) Mode. Function Code HEX/ASCII Value Full ASCII (CTRL + X Mode)
  • Page 108: Supported Interface Keys

    Country Codes Denmark Norway Spain Supported Interface Keys IBM PC/AT and Compatibles, Apple Mac/iMac ASCII USB PC Supported Keys Keyboard Reserved Reserved Enter (KP) Enter/Numpad Enter Cap Lock CAPS ALT make ALT make ALT break ALT break CTRL make CNTRL make CTRL break CNTRL break CR/Enter...
  • Page 109: Chapter 8 - Utilities

    Utilities To Add a Test Code I.D. Prefix to All Symbologies This selection allows you to turn on transmission of a Code I.D. before the decoded symbology. (See the Symbology Charts, beginning on page A-1) for the single character code that identifies each symbology.) This action first clears all current prefixes, then programs a Code I.D.
  • Page 110: Test Menu

    Note: EZConfig-Scanning requires .NET software. If .NET is not installed on your PC, you will be prompted to install it during the EZConfig-Scanning installation. 1. Access the Youjie web site at www.youjieaidc.com. 2. Click on the Resources tab. Select Software.
  • Page 111: Resetting The Factory Defaults

    8. Double click on the Setup.exe file. Follow the screen prompts to install the EZConfig-Scanning program. 9. If you’ve selected the defaults during installation, you can click on Start Menu-All Programs-Honeywell-EZConfig- Scanning. Resetting the Factory Defaults This selection erases all your settings and resets the scanner to the original factory defaults. It also disables all plugins. If you aren’t sure what programming options are in your scanner, or you’ve changed some options and want to restore the scan- ner to factory default settings, first scan the Remove Custom Defaults bar code, then scan Activate Defaults.
  • Page 112 8 - 4...
  • Page 113: Chapter 9 - Serial Programming Commands

    Serial Programming Commands The serial programming commands can be used in place of the programming bar codes. Both the serial commands and the programming bar codes will program the scanner. For complete descriptions and examples of each serial programming com- mand, refer to the corresponding programming bar code in this manual.
  • Page 114: Responses

    Data Field Usage When a query is used in place of the Data field, the query applies only to the specific command identified by the Tag and SubTag fields. Concatenation of Multiple Commands Multiple commands can be issued within one Prefix/Storage sequence. Only the Tag, SubTag, and Data fields must be repeated for each command in the sequence.
  • Page 115: Resetting The Custom Defaults

    the Minimum Message Length (MIN) is set to 2 characters; the Maximum Message Length (MAX) is set to 60 characters; and the Default setting (DFT) has no value. Resetting the Custom Defaults If you want the custom default settings restored to your scanner, scan the Activate Custom Defaults bar code below. This resets the scanner to the custom default settings.
  • Page 116 Setting Serial Command Selection Page * Indicates default # Indicates a numeric entry Azeri (Latin) KBDCTY80 Belarus KBDCTY82 Belgium KBDCTY1 Bosnia KBDCTY33 Brazil KBDCTY16 Brazil (MS) KBDCTY59 Bulgaria (Cyrillic) KBDCTY52 Bulgaria (Latin) KBDCTY53 Canada (French legacy) KBDCTY54 Canada (French) KBDCTY18 Canada (Multilingual) KBDCTY55 Croatia...
  • Page 117 Setting Serial Command Selection Page * Indicates default # Indicates a numeric entry Latvia KBDCTY42 Latvia (QWERTY) KBDCTY43 Lithuania KBDCTY44 Lithuania (IBM) KBDCTY45 2-10 Macedonia KBDCTY34 2-10 Malta KBDCTY74 2-10 Mongolian (Cyrillic) KBDCTY86 2-10 Norway KBDCTY9 2-10 Poland KBDCTY20 2-10 Polish (214) KBDCTY57 2-10...
  • Page 118 Setting Serial Command Selection Page * Indicates default # Indicates a numeric entry Shift Lock KBDSTY2 2-13 Automatic Caps Lock KBDSTY6 2-13 Emulate External KBDSTY5 2-14 Keyboard Control Character Output *Control Character Output Off KBDNPE0 2-14 *Control Character Output On KBDNPE1 2-14 Keyboard Modifiers...
  • Page 119 Setting Serial Command Selection Page * Indicates default # Indicates a numeric entry XON/XOFF On 232XON1 2-19 *ACK/NAK Off 232ACK0 2-19 ACK/NAK On 232ACK1 2-19 Scanner-Bioptic Packet Mode *Packet Mode Off 232PKT0 2-20 Packet Mode On 232PKT2 2-20 Scanner-Bioptic ACK/NAK Mode *Bioptic ACK/NAK Off 232NAK0 2-20...
  • Page 120 Setting Serial Command Selection Page * Indicates default # Indicates a numeric entry Presentation Presentation Mode PAPPST LED Illumination PWRNOL7 Medium PWRNOL15 Idle Illumination - Presentation PWRIDL0 Mode PWRIDL7 Medium PWRIDL15 *High PWRIDL50 Presentation Sensitivity Range 0-10 (*1) TRGPMS## Presentation Centering Window Presentation Centering On PDCWIN1 *Presentation Centering Off...
  • Page 121 Setting Serial Command Selection Page * Indicates default # Indicates a numeric entry Aimer Mode SCNAIM0 3-11 *Interlaced SCNAIM2 3-11 Centering Window Centering On DECWIN1 3-12 *Centering Off DECWIN0 3-12 Left of Centering Window (*40%) DECLFT### 3-12 Right of Centering Window (*60%) DECRGT### 3-12 Top of Centering Window (*40%)
  • Page 122 Setting Serial Command Selection Page * Indicates default # Indicates a numeric entry Data Format 1 ALTFNM1 Data Format 2 ALTFNM2 Data Format 3 ALTFNM3 Symbologies All Symbologies All Symbologies Off ALLENA0 All Symbologies On ALLENA1 Codabar Default All Codabar CBRDFT Settings CBRENA0...
  • Page 123 Setting Serial Command Selection Page * Indicates default # Indicates a numeric entry Interleaved 2 of 5 Default All Interleaved I25DFT 2 of 5 Settings I25ENA0 I25ENA1 Interleaved 2 of 5 Check Digit *No Check Char. I25CK20 Validate, But Don’t I25CK21 Transmit Validate, and Transmit...
  • Page 124 Setting Serial Command Selection Page * Indicates default # Indicates a numeric entry Matrix 2 of 5 Default All Matrix 2 of 5 X25DFT 6-13 Settings *Off X25ENA0 6-13 X25ENA1 6-13 Matrix 2 of 5 Message Length Minimum (1 - 80) *4 X25MIN## 6-13 Maximum (1 - 80) *80...
  • Page 125 Setting Serial Command Selection Page * Indicates default # Indicates a numeric entry UPC-A Addenda Required *Not Required UPAARQ0 6-19 Required UPAARQ1 6-19 UPC-A Addenda UPAADS0 6-19 Separator UPAADS1 6-19 UPC-A/EAN-13 with Extended *Off CPNENA0 6-19 Coupon Code Allow Concatenation CPNENA1 6-19 Require Concatenation...
  • Page 126 Setting Serial Command Selection Page * Indicates default # Indicates a numeric entry ISBN Translate *Off E13ISB0 6-25 E13ISB1 6-25 EAN/JAN-8 Default All EAN/ EA8DFT 6-25 JAN 8 Settings EA8ENA0 6-25 EA8ENA1 6-25 EAN/JAN-8 Check Digit EA8CKX0 6-25 EA8CKX1 6-25 EAN/JAN-8 Addenda *2 Digit Addenda Off EA8AD20...
  • Page 127 Setting Serial Command Selection Page * Indicates default # Indicates a numeric entry RSEENA1 6-30 GS1 DataBar Expanded Msg. Minimum (4 - 74) *4 RSEMIN## 6-30 Length Maximum (4 - 74) *74 RSEMAX## 6-30 Codablock A Default All Codablock A Settings CBADFT 6-30 *Off...
  • Page 128 Setting Serial Command Selection Page * Indicates default # Indicates a numeric entry QR Code Msg. Length Minimum (1-7089) *1 QRCMIN#### 6-36 Maximum (1-7089) *7089 QRCMAX#### 6-36 QR Code Append QRCAPP1 6-36 QRCAPP0 6-36 QR Code Page QR Code Page (*3) QRCDCP## 6-36 Data Matrix...
  • Page 129 Setting Serial Command Selection Page * Indicates default # Indicates a numeric entry KPCENA1 6-46 Korea Post Msg. Length Minimum (2 - 80) *4 KPCMIN## 6-46 Maximum (2 - 80) *48 KPCMAX## 6-46 Korea Post Check Digit Transmit Check Digit KPCCHK1 6-46 *Don’t Transmit Check Digit...
  • Page 130 Setting Serial Command Selection Page * Indicates default # Indicates a numeric entry Planet, Postal-4i, Intelligent Mail Bar Code, POSTAL29 6-44 and Postnet with B and B’ Fields On Planet Code Check Digit Transmit PLNCKX1 6-44 *Don’t Transmit PLNCKX0 6-44 Postnet Check Digit Transmit NETCKX1...
  • Page 131: Chapter 10 - Product Specifications

    Product Specifications YJ-HF500 Scanner Product Specifications Parameter Specification Mechanical Height 1.14 in. (29mm) Length 2.06 in. (52.3mm) Width 1.92 in. (49mm) Weight 1.76 oz. (50g) Electrical Input Voltage 4.5 - 5.5VDC Operating Power 2.25W (450mA @ 5VDC) Standby Power 1.25W (250mA @ 5VDC)
  • Page 132: Standard Cable Pinouts

    Standard Cable Pinouts Note: The following pin assignments are not compatible with Youjie legacy products. Use of a cable with improper pin assignments may lead to damage to the unit. Use of any cables not provided by the manufacturer may result in damage not covered by your warranty.
  • Page 133: Chapter 11 - Maintenance And Troubleshooting

    The interface cable is designed to be field replaceable. • Order replacement cables from Youjie or from an authorized distributor. • When ordering a replacement cable, specify the cable part number of the original interface cable.
  • Page 134 • Aren’t coated with frost or water droplets on the surface. • Are enabled in the scanner or in the decoder to which the scanner connects. Is the bar code displayed but not entered? The bar code is displayed on the host device correctly, but you still have to press a key to enter it (the Enter/Return key or the Tab key, for example).
  • Page 135: Chapter 12 - Technical Assistance

    Youjie or its authorized representatives. This warranty shall extend from the time of shipment for the duration published by Youjie for the product at the time of purchase ("Warranty Period"). Any defective product must be returned (at purchaser’s expense) during the Warranty Period to Youjie fac- tory or authorized service center for inspection.
  • Page 136 12 - 2...
  • Page 137: Symbology Charts

    Reference Charts Symbology Charts Note: “m” represents the AIM modifier character. Refer to International Technical Specification, Symbology Identifiers, for AIM modifier character details. Prefix/Suffix entries for specific symbologies override the universal (All Symbologies, 99) entry. Refer to Data Editing beginning on page 4-1 and Data Formatting beginning on page 5-1 for information about using Code ID and AIM ID.
  • Page 138: 2D Symbologies

    Honeywell Possible modifiers Symbology UPC-A with Add-On UPC-A with Extended Coupon Code UPC-E UPC-E with Add-On UPC-E1 Add Honeywell Code ID 5C80 Add AIM Code ID 5C81 Add Backslash 5C5C Batch mode quantity 2D Symbologies Honeywell Possible modifiers Symbology All Symbologies Aztec Code 0-9, A-C Chinese Sensible Code (Han Xin Code)
  • Page 139: Ascii Conversion Chart (Code Page 1252

    Honeywell Possible modifiers Symbology Canadian Post China Post InfoMail Intelligent Mail Bar Code Japanese Post KIX (Netherlands) Post Korea Post Planet Code Postal-4i Postnet ASCII Conversion Chart (Code Page 1252) In keyboard applications, ASCII Control Characters can be represented in 3 different ways, as shown below. The CTRL+X func- tion is OS and application dependent.
  • Page 140: Lower Ascii Reference Table

    Non-printable ASCII control Keyboard Control + ASCII (CTRL+X) Mode characters Windows Mode Control + X Mode On (KBDCAS2) Char Control + X Mode Off (KBDCAS0) CTRL + X CTRL + X function CTRL+ X CTRL+ Y CTRL+ Z CTRL+ [ CTRL+ \ CTRL+ ] CTRL+ ^...
  • Page 141 Extended ASCII Characters CP 1252 ASCII Alternate Extended PS2 Scan Code ↑ € Ç 0x48 up arrow ↓ ü 0x50 down arrow → ‚ é 0x4B right arrow ← ƒ â 0x4D left arrow „ ä Insert 0x52 … à Delete 0x53 †...
  • Page 142 Extended ASCII Characters (Continued) CP 1252 ASCII Alternate Extended PS2 Scan Code ³ │ ´ ┤ µ ╡ ¶ ╢ · ╖ ¸ ╕ ¹ ╣ º ║ » ╗ ¼ ╝ ½ ╜ ¾ ╛ ¿ ┐ À └ Á...
  • Page 143: Iso 2022/Iso 646 Character Replacements

    Extended ASCII Characters (Continued) CP 1252 ASCII Alternate Extended PS2 Scan Code ç τ è Φ é Θ ê Ω ë δ ì ∞ í φ î ε ï ∩ ð ≡ ñ ± ò ≥ ó ≤ ô ⌠ õ...
  • Page 144 Code Page Selection Method/Country Standard Keyboard Country Honeywell Code Page Option Germany ISO/IEC646-21 Switzerland ISO /IEC 646-CH Sweden / Finland (extended Annex C) ISO/IEC 646-11 Ireland ISO /IEC 646-207 Denmark ISO/IEC 646-08 Norway ISO/IEC 646-60 Italy ISO/IEC 646-15 Portugal ISO/IEC 646-16 Spain ISO/IEC 646-17 Spain...
  • Page 145: Unicode Key Maps

    Unicode Key Maps 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 4B 50 55 5A 5F 64 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 4C 51 56 5B 60 65 1F 20 21 22 23 24 25 26 27 28 29...
  • Page 146 A - 10...
  • Page 147: Sample Symbols

    Sample Symbols UPC-A Interleaved 2 of 5 1234567890 0 123456 7890 EAN-13 9 780330 290951 Code 128 Code 128 Code 39 BC321 Codabar A13579B Code 93 123456-9$ Straight 2 of 5 Industrial 123456...
  • Page 148 Matrix 2 of 5 6543210 GS1 DataBar (01)00123456789012 PDF417 Car Registration Data Matrix Test Symbol QR Code Aztec Numbers Package Label MaxiCode Micro PDF417 Test Message Test Message Postnet Zip Code...
  • Page 149 4-CB (4-State Customer Bar Code) 01,234,567094,987654321,01234567891 ID-tag (UPU 4-State) J18CUSA8E6N062315014880T...
  • Page 150: Programming Chart

    Programming Chart...
  • Page 151 Programming Chart Save Discard Reset Note: If you make an error while scanning the letters or digits (before scanning Save), scan Discard, scan the correct letters or digits, and Save again.
  • Page 152 YJ-HF500-ENUS-UG Rev A 10/15...

Table of Contents