Before Each Use; Lighting - Garden Treasures GAD1435L Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

OPERATING INSTRUCTIONS

Before Each Use:

1. Keep the outdoor firepit area clear and free from any combustible materials, gasoline, and other
flammable vapors and liquids.
2. Do NOT obstruct the flow of the combustion of LP gas and the ventilation of air.
3. Keep the ventilation opening(s) of the LP gas tank area free and clear from debris.
4. See CARE AND MAINTENANCE on page 15 for proper cleaning instructions.
5. Check all gas connections for leaks.
6. Check components for any signs of damage or rust.
7. Check for obstructions of airflow to the burner. Spiders, insects and webs can clog the burner/
venturi tube. A clogged burner/venturi tube can lead to a fire.
8. If damage to any component is detected, do NOT operate until repairs are completed.

Lighting

CAUTION
• Keep outdoor gas appliance area clear and free from combustible materials, gasoline and other
flammable vapors and liquids.
• Do NOT obstruct the flow of combustion and ventilation air.
• Check and clean burner/venturi tubes for insects and insect nests. A clogged tube can lead to a fire.
• Attempting to light the burner with a cover on it may cause an explosion.
• After lighting - using a firepit tool and heat-resistant gloves (none included), carefully move the lava
rocks back to their proper position, being careful to avoid the flame.
• If ignition does not occur in 5 seconds, turn burner control knob (E) to " OFF," wait 5 minutes, fan
with a newspaper or magazine, and repeat lighting procedure.
1. Make sure all labels, packaging and protective films have been removed from the outdoor firepit.
2. Check for obstructions of airflow to the burner.
Spiders, insects and webs can clog the
burner/venturi tube. A clogged burner tube
can lead to a fire.
3. Control knob (E) must be in the " OFF"
position (Figure 9).
4. Clear small area of lava rocks (Q) away from
the pilot housing (A).
5. Connect LP gas tank per "Connecting LP Gas
Tank" section on page 12.
6. Turn LP gas tank valve to "OPEN."
7. Push and turn control knob (E) to (HIGH).
The burner should light. If it does not, repeat
up to three times.
8. After 20 seconds, release and turn control
knob counterclockwise to adjust flame to
desired height.
9. If ignition does not occur in 5 seconds, turn
burner control knob to " OFF," wait 5 minutes,
fan with a newspaper or magazine, and repeat
lighting procedure.
9
10
14
OFF / APAGADO
E

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents