INSTALLATION
MANUAL
LHD8001
MGE Entreprise
Av. Kouwait - 8050 Hammamet
Tunisie
Tel.1: 00216 72 278 663
Tel.2: 00216 22 645 120
Email:
manager@mge-security.com
www.mge-security.com/
SECURITY SYSTEM

Advertisement

Table of Contents
loading

Summary of Contents for LONGHORN LHD8001

  • Page 1 INSTALLATION MANUAL LHD8001 MGE Entreprise Av. Kouwait - 8050 Hammamet Tunisie Tel.1: 00216 72 278 663 Tel.2: 00216 22 645 120 Email: manager@mge-security.com www.mge-security.com/ SECURITY SYSTEM...
  • Page 2: Installation Information

    INSTALLATION INFORMATION Appendix 2: Zone type setting figure Wireless zone User User address Zone number Installation position Type Bypass or not Installer Installation company Installation date Tel of installation company Fax of installation company Center stations Address of center stations Tel of center stations Tel of the control panel CONTAINER LOADING LIST...
  • Page 3: Table Of Contents

    Table of Contents Setting item Keypad operation Parameter / Select Default General introduction Auto-arm time X=1~3(NO. X auto-arm time) 35 X Y # Y=88 88 setting Y=hour minute(4 digits) Specifications X=1~3(NO. X auto-disarm time) 36 X Y # Y=88 88 Term definition Auto-disarm time setting...
  • Page 4: Zone Bypass

    6. Dimension: 250 150 45mm 9.3.13 Entry delay time adjustment 9.3.14 Year setting 9.3.15 Date setting 9.3.16 Hour and minute setting 9.3.17 Auto-arm time setting 9.3.18 Auto-disarm time setting 9.3.19 Zone definitions 9.3.20 Enroll wireless detector 9.3.21 Wireless detector canceling 9.3.22 Enroll remote controller 9.3.23 Remote controller canceling 250mm...
  • Page 5: Remote

    1. General introduction Types of fault Potential reasons Solutions This is a new kind of intelligent security product. It transmits alarm information The zone is bypassed Cancel bypass of the zone The system has no via telephone communication network and is remotely controlled to deal When disarm, zone 1,2,3 do feedback when zone is Operate normally...
  • Page 6: Term Definition

    3 . Term definition 12. Warranty Detector: A facility that detects intrusion and abnormal state Although it is an advanced and reliable security system, it does not offer automatically via some electric or physical methods guaranteed protection against burglary, fire, or other troubles. The and output switch signals or wireless signals to the limitations are as follows: system for disposal, then output alarm signals, such...
  • Page 7: Notice Before Using

    11. Control Panel Communication Code 4. Notice before using Communication between control panel and center stations have two Please set '911' as alarm phone number under the police's approval. Read the manual carefully before using formats ADEMCO 4+1 and ADEMCO Contact ID. Connect the AC power supply after other wiring is complete ADEMCO 4+1 Table of event ADEMCO Contact ID OPERATION OF...
  • Page 8 10.3 Telephone arm-stay Standby battery socket Standby battery switch Antenna Standby battery After picking up the telephone, press '# +4digits password(user Anti-tamper switch password, operation password) + 2 + #' to arm, For example, if user Bell output password is 1234, press '#12342#'. When alarm occurs, user has to disarm first and then arm the system again.
  • Page 9 10. Remote telephone operation 5.2.2 Bell output terminals The maximal drive capacity of bell terminal (+BELL -) is 400mA /12VDC User can dial telephone number of the control panel perform the operations: arm away/stay, disarm spot supervision and hearing alarm types. Connect the two power lines of the bell to 'BELL+' and 'BELL-' terminals Dial telephone number of the control panel for more than ringing attempts When the system is powered up and initialized bell will chirp once,...
  • Page 10 5.2.5 Relay output 9.3.30 All zones bypassed Enter: 910 The maximal load capacity of relay terminal ' Operations: (PROG user password Contact capacity 10VA Functions: The system can provide a command to bypass all zones. Contact maximal voltage 100VDC 9.3.31All zones reactive Enter: 920 Contact maximal current 0.5A Operations: (PROG...
  • Page 11: Operation

    6. Operation commands successfully, alarm time, alarm type, corresponding zone type and zone number display on LCD. Press '6' key to turn up '9' key to turn down 6.1 Control panel composition for continually inquiring. Flip requirement press '#' then press '80 XX #' until the last inquiring finished.
  • Page 12: Power Up The System

    6.2 Power up the system 9.3.27 Record playing Enter: 71 X Check all wiring are correct Operation: (PROG X Switch on AC power or turn on the standby battery, buzzer will beep twice; Parameters setting: X=1~8 specified alarm voice, X=9 user address record keypad backlighting and power indicator will be on.
  • Page 13: Alarm Type

    XX=21~24 (4 wired zones) 1) Zone alarm The zone will alarm if the 24- hour zone be triggered otherwise buzzer will XX=30(control panel with anti-tamper function) chirp to indicate user must disarm the system within enrty-delay. If the Bypass for all wired zones in factory default setting. Wireless zones are still zone with entry-delay be triggered, buzzer chirps, LCD displays: valid.
  • Page 14: Zone Type And Zone Assignment

    7. Zone type and zone assignment other remote controller. Changing the code learn to solve the above problem. If the problem is the above reasons, checking the detector and make sure its 7.1 Zone type carrier frequency is different from the control panel. Valid or Valid or Valid or...
  • Page 15 The factory default setting is all wireless zones are type 4(panic zone). Wired zone 21 is type 1(entry/exit zone), Wired zone 22 is type 2(active zone), Arm-away Wired zone 23 is type 3(perimeter zone) Wired zone 24 is type 4(panic zone) Arm-stay Functions: Set different zone types .It can not modify the zone types of the Disarm...
  • Page 16 2. If the system is in 'Arm-away' status and no zone alarms, press the X minute (24 hours), default is 8888. 'STAY' key on control panel, input password to enter arm-stay status or Functions: The system can set 3 groups arm time. If user wants to cancel press the 'Arm-stay' key on remote controller to enter the arm-stay some set arm time, set YYYY as 8888.
  • Page 17: Xyyyy

    XX=10 (100 seconds) 3. Disarm with remote controller, the armed indicator off when disarmed, buzzer chirps once to indicate disarm the system, LCD displays: XX=20 (200 seconds) Disarmed Year-Month-Day Hour: Minute XX=30 (300 seconds) The factory default setting is XX=04 (40 seconds) If the system is in alarm status, press the 'Disarm' key, the armed Function: The system entry-delay time adjustment.
  • Page 18 XX= 02 (2 minutes) The keyboard has been locked! XX =10 (10 minutes) Note: The keypad will be locked with fail operation. The system unlock automatically under the following status: 1. Restarting the system; 2. XX =20 (20 minutes) Waiting half an hour. XX =30 (30 minutes) 9.2 Operation step The factory default setting is XX= 10 (10 minutes)
  • Page 19: Parameters Definition: X=1 (On)

    9.3.8 Telephone line monitor Enter : 26X Note: If user want to exit program status press '*' to delete digits .When all digits are deleted, press '*' key to exit. This operation can be realized Operations: (PROG user password by pressing '#' key or one function keys .In the programming status, if Operations definition: X=1 (ON) without pressing any key for 1 minute, the system will exit present status and return to display clock and arm/disarm status.
  • Page 20 9.3.2 User address code setting Enter:20 XXXX (2)Operation password canceling Operations: (PROG user password Operations: (PROG user password XXXX Parameter definitions: X=1~5(NO.X operation password) Parameter definition: XXXX = 4 digits user address code. The factory default Functions: Password canceling. setting is 1234. Functions: After setting user address code, when alarm occurs, the center stations will determine which control panel is calling.