Assembly; Startup - Hitachi ML 36DL Handling Instructions Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 14

Assembly

ASSEMBLY
Assemble according to enclosed assembly in-
structions.
CAUTION!
The machine must not be put in opera-
tion before it has been assembled com-
pletely.

STARTUP

CHARGER
Model
Charging voltage
Weight
CHARGING BATTERY
Before using the power tool, charge the battery as follows.
1. Connect the charger's power cord to a receptacle.
When connecting the plug of the charger to a
receptacle, the pilot lamp will blink in red. (At 1-
second intervals)
2. Insert the battery into the charger.
Firmly insert the battery into the charger until the line
is visible, as shown in Fig. 2, 3.
3. Charging
When inserting a battery in the charger, charging will
commence and the pilot lamp will light continuously
in red.
When the battery becomes fully recharged, the pilot
lamp will blink in red. (At 1-second intervals) (See
Table 1)
(1) Pilot lamp indication
The indications of the pilot lamp will be as shown in
Table 1, according to the condition of the charger or
the rechargeable battery.
Before
charging
While
charging
The pilot
lamp lights
or blinks in
Charging
red.
complete
Charging
impossible
The pilot
Overheat
lamp lights
standby
in green.
UC36YRSL
14.4 V ― 36 V
0.7 kg
Indications of the pilot lamp
Lights for 0.5 seconds. Does not light for 0.5
Blinks
seconds. (off for 0.5 seconds)
Lights continuously
Lights
Lights for 0.5 seconds. Does not light for 0.5
Blinks
seconds. (off for 0.5 seconds)
Lights for 0.1 seconds. Does not light for 0.1
Flickers
seconds. (off for 0.1 seconds)
Lights continuously
Lights
(2) Regarding the temperature of the rechargeable
battery.
The temperatures for rechargeable batteries are as
shown in Table 2, and batteries that have become hot
should be cooled for a while before being recharged.
Table 2 Recharging ranges of batteries
Rechargeable
batteries
BSL3625
(3) Regarding recharging time
Depending on the combination of the charger and
batteries, the charging time will become as shown in
Table 3 .
Table 3 Charging time (At 20℃)
Charger
Battery
BSL3625
NOTE
The charging time may vary according to temperature
and power source voltage.
4. Disconnect the charger's power cord from the
receptacle
5. Hold the charger firmly and pull out the battery
NOTE
After charging, pull out batteries from the charger
first, and then keep the batteries properly.
ADVICE
The temperature range for the charging
process should between 0° C and +40°
C.
The maximum time for a full charge is
1,5 hours. If the operating period of the
battery is greatly reduced in spite of a
full charge, the battery is worn out and
should be replaced with a new original
battery.
Table 1
en
Temperatures at which the
battery can be recharged
0℃ ー 50℃
UC36YRSL
Approx. 75 min.
Malfunction in the
battery or the charger
Battery overheated.
Unable to charge
(Charging will commence
when battery cools).
17