POWERLINE CARRIER DEVICES WORKSHEET FOR ✻ ✻ ✻ ✻ 80, and ✻ ✻ ✻ ✻ 81.
Applicable only if Powerline Carrier Devices are to be used, or chime-by-zone feature is used.
U L
Powerline Carrier Devices have not been evaluated by UL.
✱ 80 OUTPUT DEVICES
Fill in the required data on the worksheet on below and follow the programming procedure in the Installation
Instructions as you enter the data during the displays and prompts that appear in sequence.
Note: Field ✱ 25 must be programmed with a House Code.
DEVICE
NUMBER
P.L.C.D.*†
01
P.L.C.D.*†
02
P.L.C.D.*†
03
P.L.C.D.*
04
P.L.C.D.*
†05
P.L.C.D.*†
06
SYS. P.L.C.D.*† 07
SYS. P.L.C.D.*† 08
E-mail Event Trigger 09
E-mail Event Trigger 10
E-mail Event Trigger 11
E-mail Event Trigger 12
E-mail Event Trigger 13
E-mail Event Trigger 14
E-mail Event Trigger 15
E-mail Event Trigger 16
* P.L.C.D. = Powerline Carrier Device (X10).
Where:
A = DEVICE ACTION
ET = EVENT TYPE
Z L = ZONE LIST
ZT = ZONE TYPE/
SYSTEM OPERATION
Note: In normal operation mode:
For Devices 1-6:
Function + Lights On + N
Function + Lights Off + N
ACTION
EVENT
ZONE
(aa)
TYPE (et)
LIST (zl)
[2]
[2]
0 = No Response; 1 = Close for 2 sec; 2 = Close and stay closed; 3 = Pulse on and off.
0 = Not used; 1 = Alarm; 2 = Fault; 3 = Trouble.
1, 2, or 3 (from Field ✱ 81) or 0 = Not Used.
"START" ZONE LIST: Upon alarm, fault, or trouble of ANY zone on this list, device action will START.
"STOP" RESTORE of ZONE LIST: Upon restore of ALL zones on this list, device action will STOP.
It need not be same list as used for START.
Note: Do not assign zones with types 20, 21, or 22 to a zone list.3
Choices for Zone Types are:
00 = Not Used
01 = Entry/Exit#1
02 = Entry/Exit#2
03 = Perimeter
04 = Interior Follower
05 = Trouble Day/Alarm Night
06 = 24 Hour Silent
Note: Any zone in "ZT" going into alarm, fault, or trouble will activate device with the
exception of 01, 02 when the system is in alarm. Any zone that restores will
stop device action.
Choices for System Operation are:
20 = Arming–Stay
21 = Arming–Away
22 = Disarming (Code + OFF)
31 = End of Exit Time
32 = Start of Entry Time
* Except ZT=08, 09, 14 or 16.
** Or at Disarming, whichever occurs earlier.
S T A R T
either or both
ZONE TYPE
SYS OPERATION (zt)
[33]
[33]
07 = 24 Hour Audible
08 = 24 Hour Aux
09 = Fire Zone without Verification
10 = Interior with Delay
14 = Carbon Monoxide
24= Silent Burglary
33 = Any Alarm*
36 = At Bell Timeout**
38 = Chime
39 = Any Fire Alarm
40 = Bypassing
For Devices 7 and 8:
Code + Function + 4 + N
Code + Function + 7 + N
- 20 -
S T O P
either or both
RESTORE
ZONE TYPE/
ZONE LIST (zl)
SYS OPERATION (zt)
42 = System Battery Low
43 = Communication Failure
52 = Kissoff
58 = Duress
N = device (unit) number
(Entry starts Device N)
(Entry stops Device N)
[36]
[36]