Specifications - Fujitsu ARU18RLF Service Manual

Hide thumbs Also See for ARU18RLF:
Table of Contents

Advertisement

SPECIFICATIONS

ELECTRICAL DATA
TYPE
INDOOR UNIT
OUTDOOR UNIT
COOLING CAPACITY
HEATING CAPACITY
POWER SOURCE
FREQUENCY
Cooling
RUNNING
CURRENT
Heating
Cooling
INPUT WATTS
Heating
E.E.R.
Cooling
COP
Heating
MOISTURE REMOVAL
AIR CIRCULATION HIGH
Cooling
MAXIMUM
CURRENT
Heating
FAN MOTOR
POWER SOURCE
High
Medium
INDOOR UNIT
Cooling
Low
Quiet
High
Medium
INDOOR UNIT
Heating
Low
Quiet
OUTDOOR UNIT Cooling
OUTDOOR UNIT Heating
2013.04.13
Cool & heat inverter
ARU18RLF
AOU18RLFC
18,000 Btu/h
21,600 Btu/h
208/230 V
60 Hz
6.6 A
7.3 A
1.50 kW
1.67 kW
12.0 Btu/Wh
12.9 Btu/Wh
4.2 Pts/h, 2.0 L/h
3
553 CFM, 940 m
/h
10.0 A
14.0 A
208/230 V
1,380 r.p.m.
1,300 r.p.m.
1,220 r.p.m.
1,140 r.p.m.
1,380 r.p.m.
1,300 r.p.m.
1,220 r.p.m.
1,140 r.p.m.
870 r.p.m.
1,000 r.p.m.
NOISE LEVEL
INDOOR UNIT
Cooling
INDOOR UNIT
Heating
OUTDOOR UNIT Cooling
OUTDOOR UNIT Heating
COMPRESSOR AND REFRIGERANT
COMPRESSOR TYPE
DISCRIMINATION
WEIGHT (with oil)
PRECHARGED REFRIGERANT
Pipe length
49 ft., 15 m
FULL CHARGE
66 ft., 20 m
ADDITIONAL CHARGE
MAXIMUM PIPING HEIGHT
REFRIGERANT TYPE
DIMENSIONS
INDOOR UNIT
H x W x D
OUTDOOR UNIT
H x W x D
WEIGHT
INDOOR UNIT
Net / Shipping
OUTDOOR UNIT
Net / Shipping
1
High
32 dB
Medium
30 dB
Low
29 dB
Quiet
27 dB
High
32 dB
Medium
30 dB
Low
29 dB
Quiet
27 dB
52 dB
55 dB
Hermetic type,
4 pole, 3 phase,
DC inverter motor,
Rotary
808-213-80
21 lb. 6 oz., 9.7 kg
2 lb. 13 oz., 1,300 g
2 lb. 13 oz., 1,300 g
3 lb. 1 oz., 1,400 g
0.22 oz/ft, 20 g/m
49 ft., 15 m
R410A
7-25/32 x 35-7/16 x 24-13/32 in.
198 x 900 x 620 mm
24-1/2 x 31-3/32 x 11-13/32 in.
620 x 790 x 290 mm
50 lb. / 59 lb.
23 kg / 27 kg
86 lb. / 95 lb.
39 kg / 43 kg

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aou18rlfc

Table of Contents