System Information - DSC PC2580 Instruction Manual

Table of Contents

Advertisement

Bell Test
With the system disarmed, press the [
Use the [<] and [>] Keys to scroll to this message. Press [6], then enter the
Master Code.
Use the [<] and [>] Keys to scroll to this message. Press [8] to turn perform
a Bell Test. When the Bell Test is selected, the bell or siren and the keypad
sounder will sound for 2 seconds. When the test is complete, press the [#]
Key to return to the "Ready" mode.
Testing Your System with the LCD600 Keypad
It is recommended that you test your system regularly. NOTE: Perform system tests in the off-peak hours,
such as early morning or late evening.
1 Call to inform your monitoring station that you are testing your system.
2
Disarm the system and ensure that this message is displayed.
Perform a Bell Test by entering [
shown here will be displayed. If a trouble condition is indicated after
3
the test, press [
finished viewing trouble conditions.
4 Activate each sensor on your system one at a time. For example, open protected doors and windows,
and walk in areas protected by motion detectors.
As each zone is activated, this message will be displayed. Use the [<] and
[>] Keys to scroll through the list of open zones. If you are opening zones
one at a time, only one zone should be displayed as being open.
When the [<] or [>] Key is pressed, a message similar to this will be
displayed to indicate which zone has been activated.
When the zone is closed, and if all zones are closed, this message will be
displayed. Continue to activate the rest of the zones on your system and
ensure that the keypad indicates when each zone is opened and closed.
5 If they are programmed for operation, press the [F], [A], and [P] keys in turn. The [F] Key will sound the
bell or siren in a pulsed mode. Enter an Access Code to silence the alarm. The [A] Key is a silent
alarm; the [P] Key may be programmed as silent or audible. If an alarm sounds, enter an Access
Code to silence the alarm.
6 If your system has a Fire Zone, activating the Fire Zone will cause the bell or siren to sound with a
pulsed tone. CAUTION: Do not use an open flame or burning materials to test a smoke detector.
Contact your installer for information on safe methods to activate a smoke detector.
7 Should the system fail to operate properly, call your alarm dealer for service.
8 When testing is complete, call and advise the monitoring station.
22
] Key.
][6][Master Code][8]; the message
][2] to view the trouble condition. Press [#] when

SYSTEM INFORMATION

Installer
___________________________________________________________________________________
Phone
________________________________
Monitoring Station: _________________________
Account Number ___________________________
CONTACTS
Name
________________________________
Name
________________________________
Name
________________________________
ZONE INFORMATION
Zone
Type
1
____________________
_______________________________________________________
2
____________________
_______________________________________________________
3
____________________
_______________________________________________________
4
____________________
_______________________________________________________
5
____________________
_______________________________________________________
6
____________________
_______________________________________________________
7
____________________
_______________________________________________________
8
____________________
_______________________________________________________
Entrance Delay ____________________________
Auxiliary Entrance Delay ____________________
SPECIAL FEATURES
[F] Key
Enabled
Disabled
[A] Key
Enabled
Disabled
[P] Key
Enabled
Disabled
KEYPADS
The following keypads are installed on your system:
________
PC2550RK Keypads
________
LED625 Keypads
________
LCD600 Message Display Keypads
Installation Date ____________________________
Telephone Number: _________________________
Phone ________________________
Phone ________________________
Phone ________________________
Protected Area
Exit Delay __________________________________
Auxiliary Exit Delay __________________________
3

Advertisement

Table of Contents
loading

Table of Contents