Recirculation Version Air Outlet - AEG X66453MVO User Manual

Hide thumbs Also See for X66453MVO:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 10
FITTING THE HOOD BODY
• Open the top suction panel and fasten it to the
hood body on the left using the pin, so that it
does not close again.
• Unlock the lower suction panel by removing the
fixing pin on the left, and open it.
• Remove the Metal grease filters using the handles
provided.
• Adjust the two screws Vr, in the brackets 11a, so
that they are at the start of their travel.
• Hook the hood body to the two brackets 11a.
• From the inside of the hood body, turn screws Vr
to level the hood body itself.
• Fasten the safety screws 11.
• Close the suction panels.
CONNECTIONS
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood
to the chimney using either a flexible or rigid pipe
ø 150 or 120mm, the choice of which is left to the
installer.
To install a ø 150 pipe
• To install the dumper 10
• Fix the pipe in position using sufficient pipe clamps
(not supplied).
To install a ø 120 pipe
• To install a ø 120 mm air exhaust connection,
insert the reducer flange 9 on the dumper 10.
• Fix the pipe in position using sufficient pipe clamps
(not supplied).
• Remove any activated charcoal filters.

RECIRCULATION VERSION AIR OUTLET

.
• Screw the filter cover onto the air outlet, using
four screws 12c (2.9 x 12.5).
• Fix the directional grille 8 on the recirculation air
outlet using the 2 screws 12d (2,9 x 9,5) pro-
vided.
EN - INSTALLATION
ø 150
10
10
8
16
14
11a
Vr
11
ø 120
9
12d
12c