National Instruments NI-DNET User Manual page 74

National instruments devicenet ni-dnet user manual
Table of Contents

Advertisement

Appendix D
Hardware Specifications
PXI-CAN Series
NI-DNET User Manual
Storage environment
Ambient temperature .......................–20 to 70 °C
Relative humidity ............................5 to 90%, noncondensing
Dimensions .............................................16.0 by 10.0 cm
Power requirement..................................+5 VDC, 775 mA typical
I/O connector ..........................................9-pin D-SUB for each port
Operating environment
Ambient temperature .......................0 to 55 °C
Relative humidity ............................10 to 90%, noncondensing
Storage environment
Ambient temperature .......................–20 to 70 °C
Relative humidity ............................5 to 95%, noncondensing
(Tested in accordance with IEC-60068-2-1, IEC-60068-2-2,
IEC-60068-2-56.)
Functional Shock ....................................30 g peak, half-sine, 11ms pulse
(Tested in accordance with IEC-60068-2-27. Test profile developed in
accordance with MIL-T-28800E.)
Random Vibration
Operating .........................................5 to 500 Hz, 0.3 grms
Nonoperating ...................................5 to 500 Hz, 2.4 grms
(Tested in accordance with IEC-60068-2-64. Nonoperating test profile
developed in accordance with MIL-T-28800E and MIL-STD-810E
Method 514.)
(6.3 by 3.9 in.)
(standard)
or
5-pin Combicon-style pluggable
DeviceNet screw terminal
(high-speed CAN only)
D-2
ni.com

Advertisement

Table of Contents
loading

This manual is also suitable for:

Devicenet ni-dnet

Table of Contents