National Instruments none User Manual page 114

National instruments home theater system user's manual
Table of Contents

Advertisement

Chapter 5
Getting Started with Measurement Studio
Measurement Studio User Manual
4.
Select Points Only. Click OK. Notice that the legend changed
automatically to match the formatting of the graph.
5.
Click the gauge smart tag to display the Gauge Tasks.
6.
Select Auto Format to display the Auto Format dialog box.
7.
Select Dark and click OK.
8.
Right-click the gauge and select Properties to display the Properties
window.
9.
Set the Range property for the gauge with the drop-down Range type
editor. Type
-0.2
maximum value.
10. Click the numeric edit smart tag to display the Numeric Edit Tasks.
11. Select Gauge in the Source drop-down list. Setting the Source
property to the gauge allows two-way binding between the controls.
12. Deselect ArrowKeys, Buttons, and Text for the InteractionMode
property of the numeric edit control. Deselecting these interaction
modes makes the numeric edit an indicator. The numeric edit control
only displays the calculated mean.
13. Select the Format Mode property and in the Numeric Edit Format
Mode Editor dialog box, change the Precision to
decimal places of precision.
14. Select File»Save Form1.cs to save your application.
for the minimum value and type
5-10
for the
0.2
to show four
4
ni.com

Advertisement

Table of Contents
loading

Table of Contents