If Pantry Panel Pcb Is Not Working Normally; If Pantry Panel Pcb Is Not Working Normally - Samsung RFG298AA series Service Manual

Hide thumbs Also See for RFG298AA series:
Table of Contents

Advertisement

TROUBLESHOOTING

4-2-11. If Pantry Panel PCB is not working normally

You should check the display after door opening because the display of this model operates only when
the fresh food compartment door is opened.
If Panel Key is not selected
Typical PCB Ground
REG1 Heater Sink
② If Panel PCB Key is not selected
※ If it is not repaired with the above basic checking method
☞ Checking method of voltage Based on
PCB typical Ground REG1 Heater Sink
1) Key voltage ; CN51#6"(Purple)
1) select(operating) (0V)
2) normal(about5.0V ±0.5V)
2) LED part voltage ; CN51-"1"(Yellow),
"2"(Pink),"3"(Orange) → Voltage of CN51
is same as IC50 #14,#13,#12 voltage.
- Display On (0.7V±0.5V)
- Display Off (11V±1V)
Start
Does fresh food
compartment door switch
operate normally?
Is the connector of
pantry room in fresh food
compartment inserted
correctly?
Is MAIN PCB
Connector (CN51) inserted
correctly?
Is signal of MAIN
PCB CN51 normal?
Is the lighting
operated when replace Pantry
Panel-PCB?
① Check the wires of Pantry Room - disconnection, short between wires
② Recheck the control circuit of MAIN PCB Pantry Panel
③ Check the wire assembling between Panel and MAIN
Is a key pressed
continuously?
Is the PCB system
still operated by separating
of the mechanism?
Is the lighting operated
after replacing the Pantry
Panel-PCB?
Is a normal voltage
outputted from MAIN PCB IC74
during the key operating?
① Check the wire of Pantry Room - disconnection, short
between wires
② Check the short/open of the pantry panel lighting
circuit in MAIN PCB.
87
Check and repair the switch
* Refer to<how to repair door switch>
Reinsert Connector,
Repair bad contact
Reinsert connector in MAIN PCB
Check voltage/Replace MAIN PCB
Panel PCB itself has trouble.
Reassemble PCB ASS'Y /
Enforce the cancelation of
pressed keys
Reassemble PCB ASS'Y /
Enforce the cancelation of
pressed keys
Convertible compartment Panel
PCB itself has trouble.
① Replace MAIN PCB
② Check the short of MAIN
Panel wire

Hide quick links: