Daisy Chain Connection
1.
Connect the Ethernet cable as shown below.
Computer
ACCELERATOR
Ethernet port
Network switch
ID#1
CASCADE OUT
ID#2
CASCADE IN
CASCADE OUT
ID#3
CASCADE IN
2.
Set the [UNIT ID rotary switch] on the rear
panel to a unique ID.
3.
Turn off (up) the [Dip switch] No.1 on the
rear panel.

Setting up the Power Supply

1.
Insert one plug of the power cable into the
[AC IN] terminal on the device.
2.
Insert the other plug of the power cable into
a proper AC wall outlet.
3.
Turn on (|) the power.
WARNING
Only use the included power cable (or an equivalent
recommended by Yamaha). Using the wrong cable can result
in damage to the device or overheating.
CAUTION
Remove the plug of the power cable from the outlet when the
device is not be used for extended periods of time, or during
electrical storms.
DANTE
PRIMARY
PRIMARY
SECONDARY
PRIMARY
SECONDARY
PRIMARY
NUAGE I/O (16D )/ NUAGE I/O (16A) / NUAGE I/O (8A8D) Operation Manual
Configuring the Audio Routing
of the Dante Network
1.
Launch Dante Controller.
2.
In the "Routing" tab on the "Network View"
window, set the audio routing by placing a
check mark at the intersection of the desired
devices.
To use the link function with Nuendo, set up as
follows.
Set the sample rate and pull-up/pull-down
parameters on NUAGE I/O and DANTE
ACCELERATOR to the same settings.
Join the inputs and outputs in the matrix. For
example, set channels 1 through 16 on NUAGE I/
O to channels 1 through 16 on DANTE
ACCELERATOR.
NOTE
For details on the Dante Controller, refer to the Dante
Controller manual.

Installing TOOLS for NUAGE

To install TOOLS for NUAGE, double-click the installer file
you have downloaded from the website. For details, refer
to the TOOLS for NUAGE installation guide.
Configuring the Workgroup on
NUAGE
To configure the Workgroup, open the NUAGE Workgroup
Manager then register the devices and DAW software
applications to the Workgroup. For details, refer to the
NUAGE Workgroup Manager manual (PDF). To open the
NUAGE Workgroup Manager manual, double-click the
NUAGE Workgroup Manager icon on the task tray
(Windows) or menu bar (Mac) for opening the window,
then click the "Manual" icon.
The setup is now completed.
Setup