5. INPUT / OUTPUT JACKS

30) AUX SEND JACK
The AUX SEND JACK provides a mono mixed signal from the
input channels to an external effects unit or other devices.
The signal is adjusted by the AUX/DSP (3) controls of each
channel and by the AUX SEND (21) control.
31 & 33) AUX 1 AND 2 RETURN JACKS
These jacks will accept the signal from an external effects unit and
other line level devices. These are adjusted by AUX 1 and 2
LEVELS (19,20) controls.
32) MONITOR OUT JACK
This jack provides a nominal line level signal for stage monitoring
purpose. Its level is adjusted by the MONITOR OUT (24) control.
34) TAPE IN L, R JACKS
These jacks will accept the signal from an external device with a
stereo output, such as a cassette recorder. The level is adjusted
by the TAPE IN (23) control.
35) TAPE OUT L, R JACKS
These jacks can be used to connect the LEFT/RIGHT output
signals to external recording devices.
36) MASTER MIX OUT JACKS
Use these jacks to connect to an external power amplifier if extra
output power for a larger P.A. system is required.
CONTROLS AND CONNECTIONS
(32)
(33)
(34)
(36)

6. REAR PANEL

37) SPEAKER OUTPUT JACKS
• RIGHT/MONITOR — Is use in STEREO MODE for right output
or MAIN/MONITOR MODE for monitor output
• LEFT/MAIN — Is used in STEREO MODE for left output or in
MAIN/MONITOR MODE for main output
• BRIDGED MODE — Is used only in BRIDGED MODE.
(Note: RIGHT/MONITOR (37) output jacks are connected in
parallel internally. LEFT/MAIN (37) output jacks are connected in
parallel internally)
(Caution: When using RIGHT/MONITOR (37) and LEFT/MAIN
(37) output jacks do not plug anything in BRIDGED output jack.
When using BRIDGE MODE do not plug anything into RIGHT/
MONITOR (37) or LEFT/MAIN (37) jacks)
38) POWER CONNECTOR
The IEC jack is used to connect the power cord to the AC Power
Source.
(Caution: Do not remove the center grounding pin.)
39) FUSE COMPARTMENT
Replace with only the same type fuse (see page 13). If it blows
continuously, do not use the unit until it has been serviced by
qualified personnel.