Summary of Contents for Guardian MIZCS
Page 1
Merge/Isolate Zone Control System Model MIZCS Installation Programming Operation P006737 Rev. C 151116 11/16/2015 11:32 AM Ph: 403.258.3100 \ email:info@guardiantelecom.com \ www.guardiantelecom.com...
The MICON has the ability to trigger and reset up to 10 alarm channels from an alarm generator, such as Guardian’s AG17. It also displays two summary alarms in the form of LED indicators. The inputs for these are located on the MICAB and are a simple dry contact format.
2 Line X 16 Character Back Lit LCD Display Hearing aid compatible receiver Extended length (up to 20ft) handset cord - Contact Guardian Sales for details Cable Entrances Includes 1 cable gland Support for two additional glands for external peripherals Mounting ...
Guardian Telecom Inc. Installation Programming Operation Merge/Isolate Zone Control System MICAB Features Construction Heavy duty Steel – Corrosion protected and powder coated. Standard 19” Rack Mount – 3U height Connectors Screw terminals accommodate up to 14 AWG cable Indicators and Controls ...
Guardian Telecom Inc. Installation Programming Operation Merge/Isolate Zone Control System Figure 3 - MICON Features Figure 4 - MICON Desk Top Mounting Figure 5 - MICON Wall Mounting Page 7...
Guardian Telecom Inc. Installation Programming Operation Merge/Isolate Zone Control System HANDSET LCD DISPLAY MICON Connector Pin # Function Merged Talk Line A VOLUME Merged Talk Line B SIDE TONE CONTROL Merged Page Line A Merged Page Line B Data Signal A...
Guardian Telecom Inc. Installation Programming Operation Merge/Isolate Zone Control System MICAB Back Panel Connector Tables (pin numbering is from left to right) Power Input Connector Aux. Alarm Input Connector Pin # Function Pin # Function Neutral Warning 1 - Dry contact input...
Guardian Telecom Inc. Installation Programming Operation Merge/Isolate Zone Control System Note: The back panel MICON 1 - 5 connectors permit connection of five See: MICAB Back MICONs. If a sixth MICON is required, the cable of the sixth MICON may be...
Guardian Telecom Inc. Installation Programming Operation Merge/Isolate Zone Control System Guardian Guardian System System Cable Wire Assignment Designation Description Cable Wire - Wire - Stripe Gauge Jacket Color Color System Power J4A/J5A Black 14 AWG J4A/J5A White 14 AWG J4A/J5A...
Guardian Telecom Inc. Installation Programming Operation Merge/Isolate Zone Control System Installation of MICABs and MICONs Installing the Merge/Isolate Master Switch Unit (MICAB) WARNING – high voltages are present in this equipment when it is connected to the power source. ...
Guardian Telecom Inc. Installation Programming Operation Merge/Isolate Zone Control System Potentiometer Adjustments on the MICABs Back Panel access Potentiometers The Page line impedance adjusting potentiometers for each of the isolated See: Figure 6 - Back Panel Wiring zones are located next to the Zone connectors on the back panels of both Connections Master and Slave MICABs.
Guardian Telecom Inc. Installation Programming Operation Merge/Isolate Zone Control System Installing Multiple Merge/Isolate Controllers (MICONs) Up to six controllers (MICONs) can be connected to the MICABs. MICON wiring Tip: There are only five connections for MICONs can be in parallel, series, or a combination of both.
Page 16
Guardian Telecom Inc. Installation Programming Operation Merge/Isolate Zone Control System Notes: 1) All MICON stations have to be programmed with a station number. The station numbers range from 1 to 6. Only station number 1 can get access to program the other functions of the MICAB.
Page 17
Guardian Telecom Inc. Installation Programming Operation Merge/Isolate Zone Control System The following table describes the MICAB registers and functions: Register code Function Description Parameter Default Settings Reg06 Master MICAB Always exists 1 = exists Reg07 MICON station #1 Assertion of its...
Guardian Telecom Inc. Installation Programming Operation Merge/Isolate Zone Control System The following table describes the MICAB Alarm registers and functions: Alarm Register Associated Zones Description Parameter Default Settings Alarm 01 1234567890 Alarm channel 1 Zone 1 to 10 All Zones...
Page 19
Guardian Telecom Inc. Installation Programming Operation Merge/Isolate Zone Control System Alternatively the operator can merge the zones requested and the caller can make the page and wait for the called party to come on the line. If a merge request comes in from an unmerged zone while a merge of other zones is in progress the operator can merge the zone from which the request is coming with the merged zones and butt in, to convey to the person that the request cannot be processed at that time.
Guardian Telecom Inc. Installation Programming Operation Merge/Isolate Zone Control System LCD Indication of System Status: • Merged Zones (Displayed at same time as Active Zones) • Active Zones (showing a station is off hook on pre-determined Talk Line in respective zone) •...
Guardian Telecom Inc. Installation Programming Operation Merge/Isolate Zone Control System Alarm Reset: The alarm can be reset by pressing the Reset switch on the Alarm Tone Generator or through the [ALM RST] on the MICON. After the reset of one alarm, if there is a queue alarm, the zones associated with the queue alarm will be merged.
Guardian Telecom Inc. Installation Programming Operation Merge/Isolate Zone Control System Field Repairs & Adjustments See: MICON Replacement Field repairs may only be carried out by qualified technicians using OEM parts. Parts Substitution of parts voids warranty and may pose a hazard to users of the equipment.
Page 23
Guardian Telecom Inc. Installation Programming Operation Merge/Isolate Zone Control System The MICAB does not accept instructions from all MICONs. Be sure all the MICON connectors are properly plugged into the MICAB receptacles. Use the [LMP TST] key to verify that all the MICONs are set up without identical station numbers.
Page 24
Guardian Telecom Inc. Installation Programming Operation Merge/Isolate Zone Control System The MICAB does not accept Alarm instructions from one particular MICON. The MICON may be programmed to block the ALR SET, ALR CLR and ALR RST keys. Convert the MICON back to recognize the Alarm instruction keys by pressing the [PVT] key and the [LMP TST] key simultaneously to get into the programming mode.
Page 25
Guardian Telecom Inc. Installation Programming Operation Merge/Isolate Zone Control System MICON displays incorrect Alarm Tone triggering channel. Check ALARM LOGIC INPUT connector for correct wiring to AG17. High/Low volume on all speakers in a zone With the Page/Talk Station volume controls within a zone set to a typical level, adjust the Zone Page Line potentiometer on the back panel of the MICABs for the proper page speaker volume.
Warranty Guardian Telecom warrants your product to be free of defects in material and workmanship for a period of one year. Guardian Telecom will repair or replace any defective unit that is under warranty free of charge. This warranty is null and void if any non-authorized modifications have been made to this product, or if it has been subjected to misuse, neglect, or accident.
Guardian products have been quality tested and are in full working order when shipped from the factory Given the rugged nature of these products shipping is not expected to damage a unit. In the unlikely event of a malfunction Guardian follows the three step procedure below.
Guardian Telecom Inc. Installation Programming Operation Merge/Isolate Zone Control System Page/Talk System Models and Options Indoor Handset Stations PTI-1 & PTI-5 P9010 AB100 Aluminum or Steel full size P9035 AB1000 Glass Reinforced Plastic hood P5550 Ambient noise sensor, single line...