ArWest AW100 Operator's Manual

Vhf modem
Hide thumbs Also See for AW100:

Advertisement

Quick Links

AW100
VHF Modem
Operator's Manual
Version 1.0
Last Revised June 17, 2010
All contents in this manual are copyrighted by ArWest Communications.
All rights reserved.The information contained herein may not be used, accessed, copied,
stored, displayed, sold, modified, published, or distributed, or otherwise reproduced without
express written consent from ArWest Communications.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AW100 and is the answer not in the manual?

Questions and answers

Summary of Contents for ArWest AW100

  • Page 1 Version 1.0 Last Revised June 17, 2010 All contents in this manual are copyrighted by ArWest Communications. All rights reserved.The information contained herein may not be used, accessed, copied, stored, displayed, sold, modified, published, or distributed, or otherwise reproduced without...
  • Page 2 www.arwestcom.com...
  • Page 3: Table Of Contents

    2.2.2. Connecting AW100 and Computer ........
  • Page 4 A.1. AW100 VHF Modem Specifications........
  • Page 5: Preface

    Thank you for purchasing this product. The materials available in this Manual (the “Manual”) have been prepared by ArWest Communications, Corp. (“ArWest”) for owners of ArWest Communications products. It is designed to assist owners with the use of AW100 and its use is subject to these terms and conditions (the “Terms and Conditions”).
  • Page 6: Regulatory Information

    Terms and Conditions. The user is granted a personal, non-exclusive, non-transferable license to use such Software under the terms stated herein and in any case only with a single AW100 or single computer. You may not assign or transfer the Software or this license without the express written consent of ArWest Communications.
  • Page 7: Fcc Class A Compliance

    Preface Regulatory Information FCC Class A Compliance FCC Class A Compliance This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 8: Manual Conventions

    Technical Assistance If you have a problem and cannot find the information you need in the product documentation, contact your local dealer. Alternatively, request technical support using the ArWest Communications World Wide Web site at: www.arwestcom.com or using E-mail address support@arwestcom.com...
  • Page 9: Chapter 1. Introduction

    These signals are demodulated and output to the RS-232 serial port. AW100 delivers a reliable radio link at up to 38.4 kbps over the air for the 25 kHz channel spacing, 30 kbps for 20 kHz, 19.2 kbps for 12.5 kHz, and 9.6 kbps for 6.25 kHz.
  • Page 10: Getting Acquainted

    Introduction Getting Acquainted LEDs 1.1. Getting Acquainted The AW100 is a rugged and very powerful external radio transceiver 146 mm wide 75 mm deep 44 mm high, 488 g. weighs 1.1.1. LEDs External LED's (see Figure 1-2) are used for Link and Line status indication:...
  • Page 11: External Antenna Connector

    Introduction Getting Acquainted External Antenna Connector 1.1.3. External Antenna Connector The external antenna connects to the BNC external antenna connector placed on the back side of AW100. Antenna Connector Figure 1-3. AW100 back side 1.1.4. Cables The AW100 package includes standard communication and power cables for configuring the modem and providing a power source to the modem.
  • Page 12: Literature

    Introduction Getting Acquainted Literature 1.1.6. Literature AW100 literature, including manuals and other product information are available on the ArWest Communications website (http://www.javad.com): • AW100 Operator’s Manual • Functional specifications 1.1.7. External Antenna (not included) Antenna type depends on the site requirements, and may be directional or omni-directional.
  • Page 13: Chapter 2. Configuration

    The socket-outlet shall be installed near the equipment and shall be easily accessible. A single external power supply is necessary to operate AW100. The external power supply needs to be Listed for US and Certified for EU countries, it needs also to be a Limited Power Source and rated for Outdoor Use and have an output rated for +9 to +16 V, 5A.
  • Page 14: Configuring Aw100

    • Programming the radio modem’s settings. • Loading the new modem firmware. See the AWLaunch Software Manual available on the ArWest Communications website for details on configuring the VHF modem. To configure the AW100 modem, have the following ready: • Computer running Windows®;...
  • Page 15: Connecting Aw100 And Computer

    The user can connect whatever connector is required to the ‘open-end’ of the cable following the correct pin protocol for this cable (CM-10001). To configure, or maintain AW100, you need to connect the modem and a computer using cable Accessory Data-Ser-Pwr Cable, DB9/DB15/SAE (p/n 14-587110-02.) Figure 2-3.
  • Page 16 Configuration Configuring AW100 Configuring AW100 3. Start AWLaunch. Figure 2-4. Main window 4. Open the Preferences tab and select the COM port the modem is connected to (Figure 2-5), and click Identify. Figure 2-5. Connect to AWLaunch www.arwestcom.com...
  • Page 17 Configuration Configuring AW100 Configuring AW100 5. Once the connection is established in the Configurations tab Identification subtab the unit’s infor- mation will appear (Figure 2-6), i.e. unit serial number, firmware, hardware and boot loader ver- sions: Figure 2-6. Identification tab •...
  • Page 18 Configuration Configuring AW100 Configuring AW100 Figure 2-7. Configurations tab. Wireless subtab 7. In the Dealer Configuration subtab set the frequency and channel spacing (Figure 2-8 on page 19). To save the changes click Save Config. button. www.arwestcom.com...
  • Page 19: Checking Firmware Version

    Figure 2-8. Dealer Configuration tab 8. When finished, click Close. 2.2.4. Checking Firmware Version Use AWLaunch to check the firmware version of your AW100. 1. Select Identification subtab of Configurations tab; 1. For both Base and Remote modems the frequency must be the same.
  • Page 20: Loading New Firmware

    AWLaunch Software Manual, available on the ArWest website. To upgrade the firmware of radio modem the following steps must be performed: 1. Download the new firmware package to your computer. 2. Connect your modem and computer. See “Connecting AW100 and Computer” on page 15 for this procedure. www.arwestcom.com...
  • Page 21 Configuration Configuring AW100 Loading New Firmware 3. Select Download Firmware subtab of Utilities tab; 4. Press Identify button (note that you may not press Identify button if identification process has been complete successfully once); 5. Press Browse button and select the firmware file which you want to download;...
  • Page 22 Configuration Configuring AW100 Loading New Firmware www.arwestcom.com...
  • Page 23: Chapter 3. Command Line Interface

    • Saving into the configuration files the configuration parameters modified through the CLI. 3.1. Command Line Interface Convention The following convention is implemented in AW100 Command Line Interface (CLI): • The Carriage Return/Line Feed (CR/LF, 0x0D/0x0A) is a command delimiter.
  • Page 24: Software Switching To Command Mode

    Command Line Interface Command Line Interface Convention Software Switching to Command Mode • A successfully performed command is replied by @00 code, if Echo Off is selected, otherwise the set value is replied. • A command with the certain [Parameter Name] and blank [Parameter List] displays the current settings for a given parameter.
  • Page 25: Hardware Switching To Command Mode

    Command Line Interface Networking Commands Hardware Switching to Command Mode 4. The unit goes to command mode and discards Escape-Sequence from input buffer. The modem is immediately ready to receive commands. At the same time it continues buffering the data received over the air since step 2.
  • Page 26 8 - “TRMB Transmitter” (used with GMSK modulation, Reserved for future use) 9 - “Transparent w/EOT” Repeater (used with GMSK and 4FSK) 10 - “Repeater” (ArWest Proprietary Simplex) 11 - “TRMB Repeater” (used with GMSK modulation, Reserved for future use) 12 - “Transparent w/EOT”...
  • Page 27: Serial Interfacing Commands

    9 – 115200 baud, a default setting Note: ArWest radio modem’s does not support data flow and parity on the maintenance serial port.The radio modem with none-dedicated maintenance serial port must keep CTS line always active in MPORT mode (DP/MP is low).
  • Page 28: Special Commands

    Command Line Interface Special Commands BOOT 3.4. Special Commands 3.4.1. BOOT The factory software image and default configuration is set for the new unit. The BOOT command is intended to reboot the unit using specified software image and selected configuration. BOOT [Parameter Name] [Parameters List] [/?] Parameter Name Parameter List...
  • Page 29: Diagnostics And Identification Commands

    (range from 01 to 99) for engineering releases and alphabetic format (A to Z) for manufacturing releases The INFO command without Parameter Name indicates all values: AW100 VHF Radio Modem, Arwest Product ID =12 S/N =000000000007 Hardware =Ver.
  • Page 30 Command Line Interface Diagnostics and Identification Commands STATE The STATE command without Parameter Name indicates all values as shown below: RSSI =-106 dBm BER =0E-0 FREQ =140.000000 MHz CHAN =-4 TEMP =23 SYNC =0 TTL1 =1 TTL2 =1 MODE =FIXED www.arwestcom.com...
  • Page 31: Appendix A. Specifications

    Appendix A PECIFICATIONS A.1. AW100 VHF Modem Specifications The following sections provide specifications for the modem and its internal components. A.1.1. General Radio Specifications Table below lists the modem’s general specifications. Table A-1. General Radio Specifications Parameter Specification Operating Frequency Range...
  • Page 32: Environmental Specifications

    Specifications AW100 VHF Modem Specifications Environmental Specifications Input/Output Serial (RS232) up to 115200 bps A.1.2. Environmental Specifications Table A-2 lists the modem’s environmental specifications. Table A-2. Environmental Specifications Parameter Specification Temperature Operating –40 C to +60 Storage –40 C to +85...
  • Page 33: Receiver Specifications

    60 dB for 12.5 kHz Channel Spacing 50 dB for 6.25 kHz Channel Spacing A.2. Connector Specifications DB15 Connector This provides DB15 connectivity for the AW100 with a DB9 for connection to a PC/CE Device for configuration. Figure A-1. DB15 Connector Table A-5. Power Connector Specifications...
  • Page 34 Specifications Connector Specifications Receiver Specifications Number Signal Name Details Reserved Do not use PWRIN DC Power between 9 and 16 VDC Data Terminal Ready Clear To Send DATAOUT Data from Modem to PC Serial Port Reserved Do not use Reserved Do not use Reserved Do not use...
  • Page 35: Appendix B. Vhf Radio Usage

    Appendix B VHF R ADIO SAGE Many countries require a license for radio users (such as the United States). Be sure you comply with all local laws while operating a VHF radio. Surveying in RTK mode has made VHF the most popular choice for communications between base and rover receivers.
  • Page 36 VHF Radio Usage www.arwestcom.com...
  • Page 37: Appendix C. Safety Warnings

    This product should never be used: • Without the user thoroughly understanding operator’s manual. • After disabling safety systems or altering the product. • With unauthorized accessories. • Contrary to applicable laws, rules, and regulations. AW100 ANGER SHOULD NEVER BE USED IN DANGEROUS ENVIRONMENTS www.arwestcom.com...
  • Page 38 Safety Warnings General Warnings www.arwestcom.com...
  • Page 39: Appendix D. Warranty Terms

    REVENUE, LOSS OF USE OF THE RADIO OR ANY ASSOCIATED EQUIPMENT, COST OF CAPITAL, COST OF ANY SUBSTITUTE EQUIPMENT, FACILITIES OR SERVICES, THE CLAIMS 1. The warranty against defects in ArWest adapter, antenna, battery, charger, or cable is 90 days. www.arwestcom.com...
  • Page 40 Warranty Terms OF THIRD PARTIES, INCLUDING CUSTOMERS AND INJURY TO PROPERTY. THIS LIMITATION DOES NOT APPLY TO CLAIMS FOR PERSONAL INJURY. SOME STATES DO NOT ALLOW LIMITS ON WARRANTIES, OR ON REMEDIES FOR BREACH IN CERTAIN TRANSACTIONS. IN SUCH STATES, THE LIMITS IN THIS PARAGRAPH AND THE PRECEDING PARAGRAPH MAY NOT APPLY.
  • Page 41 What do you like least about the manual? __________________________________________________ Optional Name _____________________________________________________________________ Company __________________________________________________________________ Address____________________________________________________________________ __________________________________________________________________________ Telephone ____________________________ Fax __________________________________ Please mail to the ArWest local office listed on the back cover. All comments and suggestions become the property of ArWest Communications. www.arwestcom.com...
  • Page 42 900 Rock Avenue, San Jose, CA 95131 USA Tel: + 1(408) 770-1790 Fax: + 1(408) 770-1799 www.arwestcom.com Copyright © ArWest Communications, 2010 All rights reserved. No unauthorized duplication.

Table of Contents