iNSTALLATiON iNSTruCTiONS
Installation test (Exhaust check) (cont.)
• Check the error code before you call for service
Error Code
tE1 or tE2
HS
PS or PF or nP
• Check the duct condition
If the test displays four bars, check the exhaust system for re-
strictions and damage. Repair or replace the exhaust system as
needed.
NOTE
When the dryer is first installed, this test should be performed to
alert you to any existing problems with the exhaust duct in your
home. However, since the test performed during normal
operation provides more accurate information on the condition
of the exhaust duct than does the installation test, the number of
bars displayed during the two tests may not be the same.
Do not interrupt the test cycle, as this could result in inaccurate
results.
Even if no bars are displayed during the test cycle, some
restrictions may still be present in the exhaust system. Refer to the
Venting the dryer section of this manual for complete exhaust
system and venting requirements.
Your dryer features Flow Sense™, an innovative sensing system
that automatically detects blockages and restrictions in dryer
ductwork. Keeping ductwork clean of lint buildup and free of
restrictions allows clothes to dry faster and reduces energy use.
Possible Causes
Temperature sensor failure
Humidity sensor failure.
Electric dryer power cord is not
connected correctly, or house power
supply is incorrect.
House fuse is blown, circuit breaker has
tripped, or power outage has occurred.
Solutions
Turn off the dryer and call for
service.
Turn off the dryer and call for
service.
Check the power supply or the
connection of power cord to the
terminal block. Refer to the
Connecting electric dryers section of
this manual for complete instructions.
• Reset circuit breaker or replace fuse.
Do not increase the fuse capacity.
If the problem is a circuit overload,
have it corrected by a qualified
electrician.
Restricted or blocked airflow
Avoid long runs or runs with multiple elbows or
bends.
Excess or crushed
Too many elbows or
transition duct
Check for blockages and lint buildup.
Make sure the ductwork is not crushed or restricted.
exhaust too long
Lint buildup or
blockage
Crushed or
damaged
exhaust