Wiring Diagram; Check Thermostat Operation - CALOR DG3000WHB-7B Installation And Operation Instructions Manual

Water radiant heating touch screen thermostat

Advertisement

WIRING DIAGRAM

230 V A C
P um p or valve
1
2
3
250V A C 8A
8A
8A
8A

CHECK THERMOSTAT OPERATION

The unit will be controlled via air sensor in the thermostat and the thermostat will determine
to activate/deactivate heating system by comparing set temperature with room temperature.
Press Up and Down key to adjust thermostat setting above room temperature 1℃ in fast heating
mode or 3℃ in slow heating mode, See configuration menu item 5. The heating should begin to
operate immediately
Configuration Menu
The configuration menu allows you to set certain thermostat operating characteristics to
your system or personal requirements.
1) Press system button till "Off" flash in the display.
2) Press DOWN to make the thermostat turn off.
3) Press CONF to enter into configuration mode.
4) The User Configuration menu is displayed in the up-right screen. Current setting is displayed
in the up-left screen.
Change The Current Setting
Current Setting
Press to Save
and Exit Confituration
230 V A C
R elay
T 1
T 2
1
2
3
250V A C 8A
8A
8A
8A
Figure 4
Configuration Menu
Advance to Next Menu
Hold for 3 Seconds
to Revert to Factory
Default Setting
5